Product Category

Got any Questions? Call us Today!

+8618758069661

service@fctel.com.cn

Or leave us a message

Online Message

Din Rail AC220V to DC12V15A/24V8A/48V5A Power Supply

View : 15
Type :
Description :

Features

IP40 protection level, thick heat dissipation aluminum alloy anodized process shell, can withstand the test of harsh environment;

With digital tube display voltage, convenient on-site voltage adjustment and service activation.

3 power supply specification: 12V15A/24V8A/48V5A full power output, small temperature rise.

With power factor adjustment (PF), PF>0.9.

Designed according to safety regulations, isolation withstand voltage greater than 1500Vac.

Designed with reference to EMC requirements, strong anti-interference ability.

Complete protection functions: output overcurrent, overload, short circuit protection.

Lightning protection function, 6KV lightning protection, can resist inductive high voltage, surge protection, etc.;

Fanless and efficient thick heat dissipation aluminum alloy heat dissipation, reducing repair time;

IP40 shell protection level, can withstand the test of harsh environment;

DIN 35mm rail or wall-mounted installation;

Wide temperature type: working temperature -40℃~ +85℃;

Full load high temperature burn-in, 100% aging test;

Parameters

Electrical Parameters & Specifications

Parameter

Model

FCP-1215G

FCP-2408G

FCP-4805G

Output

 

 

 

 

 

 

 

 

Voltage

12V

24V

48V

Current

0-15A

0-8A

0-5A

Rated Power

180W

192W

240W

Voltage Ripple (noise)

<85mVp-p

<70mVp-p

<75mVp-p

Power Factor(PF)

≥0.9

≥0.9

≥0.9

Line Regulation

±0.1%

±0.1%

±0.1%

Load Regulation

±0.3%

±0.3%

±0.3%

Work Efficiency

>=91.%

>=93%

>=91%

Start-up & Rise Time

800ms,52ms/220Vac;1000ms,54mS/110Vac(At full load)

Input

 

 

 

Voltage Range

100vc–240Vac;

Alternating Current

0.96A/220 volt,1.9A/110 volt

Frequency Range

47-63Hz

Lightning Strikes & Surge

6KV lightning protection, surge current: cold start <40A/230VAC

Protect

 

 

Output Short Circuit

Hiccup mode, output can be automatically restored after fault is cleared

Output Over Current

Rated output current 130%-200%

Output Overload

Rated output power 130%-200%

Environment

 

 

 

 

 

Operating Temperature

-40℃—+85℃

Working Humidity

20-90% RH (No condensation)

Storage Temperature

-40℃—+85℃

Storage Humidity

10-95% Relative humidity

Vibration

10-500Hz, 2G 10min/cycle, 60min each for X, Y and Z axis

MTBF

>100,000 hours

Specification

 

Dimensions

(L x W x H)

110mm*81.1mm*45mm

Weight

0.8kg

 
Remark
1.Unless otherwise specified, all specifications and parameters are measured at 220Vac input, rated load, and 25℃ ambient temperature.
2.Voltage noise measurement method: Use 30cm double-stripe wire to connect 1 0.1uF and 1 10uF capacitor in parallel, and measure with a bandwidth of 20MHz.
3.Accuracy: includes setting error, linear adjustment rate and load regulation
4.Linear regulation rate measurement method: Under the condition of rated output power, adjust the input voltage within the full range and measure the output voltage change rate.
5.Load regulation rate measurement method: Measure the output voltage change rate when the output current is adjusted within the full range.

Product Size

                   