+8618758069661 [email protected]

Rackmount 8-Serial / 64-I/O 4G/LoRa Server

Model:FCT-6700-G4
2 +2

Collect serial and I/O signals in one rack unit

  • Configure serial and I/O independentlySpecify up to eight serial ports and up to 64 digital or analog channels in two-channel groups.
  • Use cellular backup for the wired linkFour Gigabit Ethernet ports support wired connectivity. Choose 4G Cat.4 or 5G RedCap for cellular service.
  • Connect local controls and remote monitoringLink a PLC or HMI locally, forward received LoRa data and report to the platform via MQTT.

Purpose & applications

  • Aggregate serial instrument readings, contact states and analog signals in pump stations and power distribution rooms.
  • Connect local monitoring equipment over Gigabit Ethernet and use a selected cellular service for the backup uplink.
  • Specify the I/O ranges, power supply and radio configuration to match the installation.

Key Features

Serial & I/O
Up to eight serial ports and 64 I/O channels, independently configured.
Cellular
Cat.4 or RedCap, dual-SIM single standby and eSIM support.
LoRa
One data access channel. Frequency configuration depends on the project.
Installation
Fanless 19-inch rack mounting, with AC and DC power options.

Serial Signals & Wiring
StandardSignalStandards
RS-232RXD, TXD, GNDEIA/TIA-232(ITU-T V.28)
RS-422TxD+, TxD−, RxD+, RxD−EIA/TIA-422(ITU-T V.11)
RS-485 four-wireTxD+, TxD−, RxD+, RxD−EIA/TIA-485
RS-485 two-wireA(TX+), B(TX−), GNDEIA/TIA-485
Power Supply Options
ItemSpecification
Input Power SupplyOptional: AC 220 V, DC −48 V, DC 24 V, or DC 110 V.
Dual power supply combinationOptional: AC+AC, AC+DC, or DC+DC.

Hardware & Environment
ItemSpecification
Processing platformIndustrial processor running OpenWrt.
Electrical Ethernet4 × RJ45, 10/100/1000BASE-T auto-negotiation, full/half-duplex adaptation, supports Auto MDI/MDIX. The MAC address table can learn 4096 addresses.
Serial Port1–8 channels configurable. Each channel supports RS-232/RS-422/RS-485; three-in-one interface type can be configured via Web.
I/O resourcesUp to 64 DI/DO/AI/AO channels, configured in groups of 2. Serial ports and I/O can be configured simultaneously.
Installation and Heat Dissipation19-inch rack mount, fanless. Physical dimensions: 440 × 199 × 44 mm, approximately 2.27 kg. With mounting ears, dimensions are approximately 485 × 200 × 45 mm (width × depth × height).
EnvironmentOperating and storage temperatures: −40–+85 °C; operating humidity: 0%–95% RH, no condensation. RedCap cellular module operates at −35–+75 °C; expansion range: −40–+85 °C; overall applicable range is confirmed on order.
ReliabilityMTBF >100,000 hours, with watchdog and system monitoring protection.
Acquisition & Control
ItemParametersTechnical Specifications
Channel configurationUp to 64 channels, configured in groups of 2, can combine DI, DO, current-type or voltage-type AI/AO.
Digital input DISupports dry contact, NPN/PNP transistor wet contact, or pulse input.
Digital output DODry contact · output formSignal relay
Dry contact · rated load30 VDC/2 A
Dry contact · maximum switching frequency50 Hz
dry contact · response time<1.2 ms
dry contact · surge protectionnone
wet contact · output modeoptical MOS relay / pulse output
wet contact · rated load245 VDC/0.12 A
wet contact · output level0–VCC (VCC is the power supply voltage of the device)
Wet contact · Response time<0.6 ms
Wet contact · Surge protectionTVS + solid discharge tube
Current input/outputRange0–20 mA (including 4–20 mA)
Resolution12 bits
Sampling rate20,000 times/s
Delay<0.1 ms
Normal temperature accuracy0.2%
Input resistance125 Ω
Output load capability600 Ω
Voltage input/outputRange0–10 V (including 0–5 V) or −5–+5 V
Resolution12 bits
Sampling rate20,000 times/s
Delay<1 ms
Normal temperature accuracy0.2%
Input resistance100 kΩ
Output load capability600 Ω
Communications & Management
ItemSpecification
Basic protocolTCP, UDP, ARP, ICMP, HTTP, DNS, DHCP, SNMP, Telnet, SSH. Supports cross-gateway/cross-routing and automatic connection recovery after network interruption.
Data accessModbus TCP Server, standard TCP/IP Socket. TCP supports multiple connections; UDP supports single-machine or multi-machine communication.
Digital control managementSupports SNMP Get/Set, used for reading inputs, reading or setting output states. Supports via touch screen, PLC local control or display.
Serial Port NetworkingSupports Modbus RTU to Modbus TCP, SSL serial data encryption, MQTT multi-topic publishing and subscription, and transparent transmission.
JSON and cloud integrationSupports Modbus to JSON, parsing of JSON sent by the server and scheduled reporting. Can connect to Huawei Cloud, Alibaba Cloud, and Mobile Cloud via MQTT.
Configuration and UpgradeWindows configuration tool, SSH, Telnet, Web and SNMP management, supports access control, quick configuration, local and remote firmware upgrade.
Wired ConnectionLAN supports ARP, Ethernet, STP. WAN supports static IP, DHCP, PPPoE, PPTP, L2TP.
Surge Protection
ItemSpecifications or technical requirementsDescription
Digital interfaceDifferential mode 6 kV, common mode 6 kVReduce the impact of induced high voltage and switch operation surges on the signal circuit.
Serial interfaceDifferential mode 6 kV, common mode 6 kVUsed for surge protection of serial line transmission.
Ethernet interface (RJ45)4 kVReduce the risk of transient overvoltage transmitted through network cables.
Digital and serial interface test basis: IEC 61000-4-5, open-circuit voltage waveform 10/700 μs, test source impedance 40 Ω.
LoRa Communication
ItemSpecification
Function1 LoRa data access channel, forwarding received LoRa data to the network.
Radio FrequencyAvailable from 400–520 MHz, default is 490 MHz. Default transmission power is 20 dBm (100 mW).
Air interface0.018–37.5 kbps, nominal reception sensitivity can reach −139 dBm.
Typical range4–8 km, actual performance depends on terrain, antenna, site interference, and local regulations.
Antenna interfaceSMA, internal pin with external thread.
Cellular Access
ItemSpecification
4G Cat.4LTE FDD/TDD, 3GPP Rel-9, no carrier aggregation. Theoretical peak of the module: FDD downlink/uplink 150/50 Mbps, TDD 130/30 Mbps.
5G RedCap3GPP Rel-17 RedCap, Sub-6 GHz, supports 5G NR SA and LTE Cat.4 fallback. Theoretical peak of the module: 5G SA downlink/uplink 226/120 Mbps; LTE downlink/uplink 150/50 Mbps, actual performance depends on network configuration.
Connection and AuthenticationSupports APN and VPDN, compatible with IoT cards, regular mobile cards, and dedicated cards. Supports CHAP, PAP, MS-CHAP, MS-CHAPv2, or no authentication.
Dual SIM and Switching2 SIM card slots, dual SIM single standby, supports eSIM (requires operator activation). Can switch operators according to configuration, using one cellular connection at a time. The front panel has 2 SMB antenna ports, with connections based on selected antenna configuration.
Link FailoverAfter the wired link fails, it can switch to cellular, with automatic detection of wired recovery. Switching and recovery time are affected by the on-site network and configuration.
Regional Frequency Bands

4G Cat.4

Standard-CN-AU-EU
RegionChina / IndiaLatin America/Australia/New ZealandEMEA / Southeast Asia
LTE-FDDB1/3/5/8B1/2/3/4/5/7/8/28/66B1/3/5/7/8/20/28
LTE-TDDB34/38/39/40/41B40B38/40/41
WCDMAB1/5/8B1/2/4/5/8B1/5/8
GSMEGSM900/DCS1800GSM850/EGSM900/DCS1800/PCS1900EGSM900/DCS1800

5G RedCap

Standard-CN-EU
RegionChinaEMEA/Southeast Asia/Australia/New Zealand
5G NR SAn1/3/5/8/28/40/41/78/79n1/3/5/7/8/20/28/38/40/41/77/78
LTE-FDDB1/3/5/8B1/3/5/7/8/20/28
LTE-TDDB34/38/39/40/41B38/40/41/42/43

EMEA refers to Europe, the Middle East, and Africa. The frequency band, operator, and on-site coverage at the installation location must be verified before connection. The cellular antenna solution and RedCap expansion temperature conditions are confirmed according to the order.

Multi-signal Acquisition and Remote Monitoring

Connect instruments and I/O for local monitoring, send data over the wired uplink, and use the selected cellular service for failover. The drawing shows an example configured with 4G.

Configure Serial, I/O and Cellular

Choose up to eight serial ports and 64 I/O channels. I/O choices advance in pairs. Power, LoRa settings and signal ranges are specified with the order.

Ordering model FCT-6700-G4UF-CN Inquire About This Configuration
Model Codes

FCT-6700-G4 / Interface code + quantity / UF or UR / Region

NONameDefinition
01FC / TFC stands for Feichang; T stands for industrial gateway.
02670019-inch rack series.
03G44-channel Gigabit RJ45 copper Ethernet ports.
04D/R/X/SRepresent RS-485, RS-232, RS-422, or selectable RS-232/422/485 serial port respectively. The configuration quantity shall not exceed 8.
05K/JK stands for DI; J stands for DO. Configured in groups of 2 channels.
06A/M/V/YA stands for current input; M stands for current output; V stands for voltage input; Y stands for voltage output. The total number of channels with DI/DO shall not exceed 64.
07Cell and regionUF is 4G Cat.4 (-CN, -AU, -EU); UR is 5G RedCap (-CN, -EU); choose one. The region suffix is placed at the end.
Ordering Examples
ModelConfiguration
FCT-6700-G4-CNOfficial website: abbreviated version of 4G Cat.4 for China; serial ports, I/O, and other options shall be specified in the order.
FCT-6700-G4S8K16J16A16M16UF-CN8-channel three-in-one serial port + 16 DI + 16 DO + 16 current AI + 16 current AO, 4G Cat.4 Chinese version.
FCT-6700-G4S8K16J16V16Y16UR-EU8-channel three-in-one serial port + 16 DI + 16 DO + 16 voltage AI + 16 voltage AO, 5G RedCap European region configuration.

The order shall specify serial port format and channels, number of various I/O channels, range and input/output types, cell version and region, LoRa configuration, power input, and single/double power combinations.

Serial, I/O and power

2 questions
01QCan serial and I/O channels be used together?+ Expand− Collapse
A
Yes. Configure up to eight serial ports and 64 I/O channels independently. I/O is ordered in groups of two.
02QWhat power inputs are available?+ Expand− Collapse
A
Specify AC 220 V, DC −48 V, DC 24 V or DC 110 V when ordering. The dual-supply combinations are AC+AC, AC+DC and DC+DC.

Connectivity and installation

3 questions
03QCan it switch from the wired uplink to cellular?+ Expand− Collapse
A
Yes. It can fail over to cellular on loss of the wired link and detect wired recovery. Timing depends on the site network and configuration.
04QCan both SIM cards connect at the same time?+ Expand− Collapse
A
The unit supports dual-SIM single standby. It uses one cellular connection at a time. eSIM needs carrier activation.
05QHow much rack space does it need?+ Expand− Collapse
A
The fanless enclosure mounts in a 19-inch rack. Allow about 485 × 200 × 45 mm including the mounting ears, plus space for wiring and antenna connections.

Related Technical Guides

Compare Ordering Examples

ModelConfiguration
FCT-6700-G4-CNOfficial website: abbreviated version of 4G Cat.4 for China; serial ports, I/O, and other options shall be specified in the order.
FCT-6700-G4S8K16J16A16M16UF-CN8-channel three-in-one serial port + 16 DI + 16 DO + 16 current AI + 16 current AO, 4G Cat.4 Chinese version.
FCT-6700-G4S8K16J16V16Y16UR-EU8-channel three-in-one serial port + 16 DI + 16 DO + 16 voltage AI + 16 voltage AO, 5G RedCap European region configuration.

Send a product inquiry

Tell us your application, quantity and preferred configuration.

We use your information only to respond to this inquiry.