+8618758069661 [email protected]

5-Port Industrial Cellular Gateway

Model:FCT-6300-F5
6,912 +6

Connect field devices through wired or cellular networks

  • Five Fast Ethernet portsFour LAN ports connect local equipment; one WAN port provides the wired uplink.
  • Two shared serial / I/O groupsChoose one serial port or two same-type I/O channels per group: up to two serial ports or four I/O channels.
  • Choose Cat.4 or RedCapWired / cellular backup and dual-SIM single standby; Wi-Fi and PoE PSE are order options.

Purpose & applications

Bring instruments, controllers and on-site data onto a wired or cellular network.

  • Field connectivityWater monitoring, industrial automation and energy management.
  • Flexible interfacesChoose a serial port or two same-type I/O channels in each of two resource groups.
  • Platform integrationOpenWrt, Modbus RTU-to-TCP conversion and MQTT / JSON reporting.

Key Features

Ethernet
4 LAN + 1 WAN, all 10/100 Mbps
Cellular
4G Cat.4 or 5G RedCap; eSIM support
Backup
Wired / cellular failover; dual SIM single standby
Options
2.4 GHz Wi-Fi and five-port PoE PSE
Installation
Aluminum enclosure; DIN rail or wall mounting

The gateway uses dual DC 9–70 V inputs. DC 48–55 V is required when PoE is enabled. Optional five-port PoE PSE powers external equipment; it is not a PoE input for powering the gateway.

01Interfaces, Power & Acquisition

Hardware Specifications

Communication interfaces
ProcessorIndustrial-grade 32-bit communication processor
LAN4 x RJ45, 10/100 Mbps, auto-negotiated full / half duplex
WAN1 x RJ45, 10/100 Mbps, auto-negotiated full / half duplex
Ethernet featuresAuto-MDI/MDIX; 4,096-entry MAC address table
Serial / I/O2 x RS-232 / RS-422 / RS-485, selected when ordering. Each serial resource can be replaced by 2 DI / 2 DO / 2 AI / 2 AO of the same type, up to 4 I/O channels in total.
SIM / eSIM2 physical SIM slots; dual-SIM single standby; eSIM supported
Antenna interfaces4G: cellular + Wi-Fi. RedCap: dual cellular without Wi-Fi, or single cellular + Wi-Fi
Power connector4-position pluggable terminal, 5.08 mm pitch

Serial rate: 300–150,000 bps. RS-232: RXD / TXD / GND; two-wire RS-485: A / B / GND. RS-422 and four-wire RS-485: TxD+ / TxD- / RxD+ / RxD- / GND. Interface types are selected when ordering.

Mechanical and environmental specifications
Dimensions110 × 86 × 40 mm
Enclosure & coolingAluminum-alloy enclosure; fanless cooling
Ingress protectionIP40
Mounting35 mm DIN rail or wall mounting
Weight0.55 kg per unit
Operating temperature4G: -40 to +85 degC; see the RedCap temperature note
Storage temperature-40 to +85 degC
Operating humidity0-95% RH, non-condensing
Wireless LAN
Wireless LAN2.4 GHz, IEEE 802.11b/g/n, single antenna; theoretical wireless rate up to 150 Mbps

Wireless rates are theoretical peaks; actual traffic depends on network, antennas and load. Ethernet ports operate at 10/100 Mbps.

Serial & Acquisition Interfaces

Serial PortsI/OExample Configuration
2 channels0 channelsD2: 2 x RS-485
1 channel2 channelsD1K2: 1 x RS-485 + 2 DI
0 channels4 channelsK2J2: 2 DI + 2 DO

Two resource groups: each provides one serial port OR two same-type I/O channels. Do not add the maximum 2 serial ports and 4 I/O channels together.

Electrical & Acquisition

Power & PoE
Gateway power inputDual redundant DC 9-70 V inputs; DC 48-55 V when PoE is enabled
ProtectionOverload and reverse-polarity protection
Gateway consumptionLess than 3 W without PoE
PoE role & portsOptional PSE power output on 5 Ethernet ports
PoE input requirementGateway DC input must be 48-55 V when PoE is enabled
PoE output capability5 ports support IEEE 802.3at; confirm the available total simultaneous output for the specific project
Acquisition interface options
Serial / I/O relationshipEvery two I/O channels of the same type replace one serial port; two resource groups, up to 4 I/O channels
Allowed combinationsEach group: one serial port or 2 DI / 2 DO / 2 AI / 2 AO. Combine the two groups without allocating a resource twice
Digital input (DI)Dry contact or NPN / PNP transistor input
Digital output (DO)Dry contact: 30 VDC / 2 A. MOS / optical MOS: 24 VDC / 0.12 A.
Analog characteristics12-bit resolution; sampling rate 1,000 samples/s
Analog input ranges0-20 mA, 4-20 mA, 0-5 V, 0-10 V, -5 to +5 V

Choose 2 serial ports, 1 serial + 2 I/O, or 4 I/O. Confirm signal types and ranges with the order. The listed analog-input ranges do not establish analog-output ranges.

The RedCap cellular module operates at −35°C to +75°C, with an extended module range of −40°C to +85°C. Confirm extension conditions and complete-device applicability with the order.

Cellular Versions & Antennas

Cellular versions
4G Cat.4UF; LTE FDD / TDD, without carrier aggregation
5G RedCapUR; Release 17, 5G SA / LTE Cat.4; see regional bands

RedCap Antenna Selection

ConfigurationApplication PriorityOrdering Code
2 cellular antennas, without Wi-FiPrioritize cellular receptionUR (dual cellular)
1 cellular antenna + 2.4 GHz Wi-FiWi-Fi required alongside cellularUWUR (single cellular)

Test reception, throughput and connection stability on site when using a single cellular antenna in weak-signal or multipath conditions.

02Cellular Versions & Theoretical Rates
Cellular versionsSupported NetworkModule Theoretical Downlink / Uplink
4G Cat.4LTE FDD / TDDFDD: 150 / 50 Mbps; TDD: 130 / 30 Mbps
5G RedCap5G SA / LTE Cat.45G SA: 226 / 120 Mbps; LTE: 150 / 50 Mbps (module theoretical peaks).

Theoretical peaks depend on module configuration and network support. Traffic through a single Fast Ethernet port is limited by its 100 Mbps rate and protocol overhead.

03Networking & Software Functions

Networking & Software

Operating system: OpenWrt

Network and data functions
Wired accessStatic IP, DHCP, PPPoE
Cellular accessCellular dial-up; APN / VPDN private networks
Dial-up authenticationCHAP, PAP, MS-CHAP, MS-CHAPv2, or no authentication
Link backupWired / cellular backup, wired recovery detection and dual-SIM failover
Connection maintenanceHeartbeat and online detection, reconnection, watchdog and system monitoring
RoutingNAT, PAT, DMZ, port mapping, virtual server, DDNS
FirewallSPI stateful packet inspection and iptables firewall configuration
VPN compatibilityPPTP / L2TP; configurable redial intervals and attempts
Device managementWeb management / upgrade; SMS connection control and status notification
Wi-Fi managementWireless repeater, WDS bridging, guest network, scheduling, regional channels and transmit-power adjustment
Serial tunnelingTCP / UDP Server, Client
Protocol conversionModbus RTU to Modbus TCP
MQTT dataMulti-topic publish / subscribe, MQTT tunneling, Modbus-to-JSON conversion, incoming JSON parsing and periodic reporting

Dual SIM is single standby; two cellular connections do not operate simultaneously. eSIM requires carrier provisioning. Link switching and service recovery depend on network conditions and configuration.

04Regional Versions & Supported Bands

Cellular Regions & Frequency Bands

4G Cat.4 regional bands

Model / Region-CN-AU-EU
RegionChina / IndiaLatin America / Australia / New ZealandEMEA / Southeast Asia
LTE-FDDB1/3/5/8B1/2/3/4/5/7/8/28/66B1/3/5/7/8/20/28
LTE-TDDB34/38/39/40/41B40B38/40/41
WCDMAB1/5/8B1/2/4/5/8B1/5/8
GSMEGSM900 / DCS1800GSM850 / EGSM900 / DCS1800 / PCS1900EGSM900 / DCS1800

5G RedCap regional bands

Model / Region-CN-EU
RegionChinaEMEA / Southeast Asia / Australia / New Zealand
5G NR SAn1/3/5/8/28/40/41/78/79n1/3/5/7/8/20/28/38/40/41/77/78
LTE-FDDB1/3/5/8B1/3/5/7/8/20/28
LTE-TDDB34/38/39/40/41B38/40/41/42/43

Regional suffixes depend on cellular version: CN / AU / EU for Cat.4; CN / EU for RedCap. For Australia and New Zealand, choose Cat.4 AU or RedCap EU. EMEA means Europe, the Middle East and Africa. Verify operator bands and local coverage before deployment.

Each application is shown separately. Click an image to enlarge it on this page.

01

Water Pump Station · Remote Monitoring

Pump-station example: 1 RS-485 + 2 AI. The PLC handles local control; the gateway acquires data and provides remote communications. A 4G configuration is shown.

Click to enlarge on this page. Interfaces and platform options follow the project configuration.
02

Industrial Automation · Device Connectivity

Automation example: the PLC connects over Ethernet and serial instruments connect over RS-485. Wired and cellular links provide remote access and backup according to configuration.

Click to enlarge on this page. Interfaces and platform options follow the project configuration.
03

Power Room · Energy Monitoring

Energy-monitoring example: two RS-485 ports collect meter and environmental-instrument data for a remote business platform. The platform is a project option.

Click to enlarge on this page. Interfaces and platform options follow the project configuration.

These are typical application illustrations, not installation wiring diagrams. Confirm sensor types, separate power supplies, PoE loads and grounding for the project. A 4G configuration is shown; RedCap uses the ordered antenna arrangement.

Build Your Ordering Model

Choose interfaces and network options to generate the corresponding complete ordering model.

Generated Ordering ModelFCT-6300-F5D2UF-CN

2 serial ports · 0 I/O channels

Inquire About This Configuration

01Model Naming Rules & Complete Examples
FCT-6300-F5Interface code + quantityUWUF / UR-P-CN / -AU / -EU
Company + typeSeries5 Fast Ethernet portsFor example D2, D1A2Optional Wi-FiChoose one cellular versionOptional PoE4G: CN / AU / EU; RedCap: CN / EU

An interface letter is followed by its quantity: D2 = 2 RS-485 ports; D1A2 = 1 RS-485 port + 2 current inputs. Wireless codes are ordered UW + UF / UR. Omit UW without Wi-Fi.

NOItemDefinition
1CompanyFC = FCTELE
2Product typeT = industrial gateway
3Series6300 = 110 mm industrial DIN-rail series
4Port specificationEthernetF = Fast Ethernet; F5 = 5 Fast Ethernet RJ45 ports, fixed as 4 LAN + 1 WAN.
Serial PortsD = RS-485; R = RS-232; X = RS-422.
DI / DOK = digital input (DI); J = digital output (DO).
AI / AOA = current input; M = current output; V = voltage input; Y = voltage output.
5Wireless configurationUW = optional 2.4 GHz Wi-Fi; UF = 4G Cat.4; UR = 5G RedCap. Choose UF or UR.
Other wireless codesUL = LoRa; UX = Wi-Fi 6; UB = Wi-Fi 7; UO = 4G Cat.1; UG = full-featured 5G. These are general naming references, not confirmed options for this model.
6eSIM / PoEeSIM supported, subject to carrier provisioning. -P = optional five-port standard PoE PSE, available for 4G and RedCap. DC 48-55 V is required when enabled. Omit -P without PoE.
7Regional suffixCat.4: -CN / -AU / -EU. RedCap: -CN / -EU. Place the regional suffix last; see the band tables.

Complete Model Examples

Example Ordering ModelConfiguration Details
FCT-6300-F5D2UWUF-P-CN2 RS-485 + Wi-Fi + 4G Cat.4 + PoE, China version
FCT-6300-F5D2UF-CN2 RS-485 + 4G Cat.4, without Wi-Fi / PoE, China version
FCT-6300-F5D2UR-P-CN2 RS-485 + RedCap-CN + PoE, dual cellular antennas, without Wi-Fi
FCT-6300-F5D2UR-P-EU2 RS-485 + RedCap-EU + PoE, dual cellular antennas, without Wi-Fi
FCT-6300-F5D2UWUR-P-EU2 RS-485 + RedCap-EU + Wi-Fi + PoE, single cellular antenna
FCT-6300-F5D1A2UF-CN1 RS-485 + 2 current inputs + Cat.4, without Wi-Fi / PoE

All examples provide 4 LAN + 1 WAN and eSIM support. RedCap uses dual cellular antennas without Wi-Fi, or a single cellular antenna with Wi-Fi; assess site signals for the latter. Every two same-type I/O channels replace one serial port.

FCTELE cloud deployment is optional; video needs a separate video platform. Confirm antennas, power supplies, mounting accessories and the simultaneous PoE output budget for the order and project.

Product & ordering

3 questions
01QWhat are the five Ethernet ports on FCT-6300-F5?+ Expand− Collapse
A

Four RJ45 LAN ports and one RJ45 WAN port, all 10/100 Mbps. FCT-6300-F5 has five copper Ethernet ports and no SFP port.

02QCan all 2 serial ports and 4 I/O channels be used simultaneously?+ Expand− Collapse
A

No. Serial and I/O share two resource groups. Each group supports one RS-232 / RS-422 / RS-485 port, or two DI, DO, AI or AO channels of the same type. Select 2 serial ports, 1 serial + 2 I/O, or 4 I/O channels when ordering.

03QHow is 1 RS-485 plus 2 current inputs encoded?+ Expand− Collapse
A

Use interface code D1A2. The datasheet example FCT-6300-F5D1A2UF-CN means 1 RS-485 port, 2 current inputs and China-version 4G Cat.4, without Wi-Fi or PoE. Confirm the input range when ordering.

Cellular & networking

5 questions
04QCan two SIMs connect simultaneously, and how is eSIM used?+ Expand− Collapse
A

The two physical slots operate in dual-SIM single-standby mode: only one cellular connection is active at a time. Dual-SIM failover and wired / cellular backup are supported. eSIM needs carrier provisioning; switching and application recovery depend on the site network and configuration.

05QCan RedCap use dual cellular antennas and Wi-Fi together?+ Expand− Collapse
A

The datasheet specifies two arrangements: UR uses dual cellular antennas without Wi-Fi; UWUR uses one cellular antenna with 2.4 GHz Wi-Fi. For Wi-Fi configurations, assess site reception and test weak-signal or multipath performance.

06QWhich regional version applies to China, Europe or Australia?+ Expand− Collapse
A

4G Cat.4 uses -CN, -AU or -EU; RedCap uses -CN or -EU. Australia and New Zealand use -AU for Cat.4 and -EU for RedCap. Confirm the band tables, carrier network and site coverage.

07QCan it convert Modbus and report MQTT JSON data?+ Expand− Collapse
A

The datasheet lists Modbus RTU-to-TCP conversion, multi-topic MQTT publish / subscribe, tunneling, Modbus-to-JSON conversion, incoming JSON parsing and periodic reporting. Validate instrument registers, platform topics and data formats with the delivered firmware.

08QWhat should I check if the cellular connection fails?+ Expand− Collapse
A

Check the selected regional bands and local operator coverage, SIM activation, APN and authentication settings, antenna connections and power input. Review Web status and test the installed location. A module peak rate is not a guaranteed application throughput.

Power & installation

3 questions
09QDoes PoE power the gateway or other devices?+ Expand− Collapse
A

PoE is optional five-port PSE output for compatible powered devices, identified by -P. The gateway requires DC 48-55 V when it is enabled. The five ports support IEEE 802.3at; confirm the available simultaneous total output for the project.

10QCan both 4G and RedCap versions include PoE?+ Expand− Collapse
A

Both cellular versions offer optional PoE PSE. Non-PoE configurations accept dual DC 9-70 V inputs. When PoE output is enabled, input must be DC 48-55 V; check supply capacity together with the load.

11QHow should dimensions and operating temperature be checked?+ Expand− Collapse
A

The aluminum enclosure measures 110 x 86 x 40 mm and supports 35 mm DIN rail or wall mounting. The 4G operating range is -40 to +85 degC. The RedCap module range is -35 to +75 degC; confirm extended -40 to +85 degC conditions and the complete-unit range with the order.

Compare Industrial Cellular Gateways

Compare fixed interfaces and shared resources before choosing a configuration.

FeatureFCT-6300-F5FCT-6300-F2B1
Ethernet4 LAN + 1 WAN, all RJ45 10/100 Mbps1 WAN RJ45 + 1 LAN RJ45 + 1 SFP LAN, all 100 Mbps
Shared resources2 groups: up to 2 serial ports OR 4 I/O channels4 groups: up to 4 serial ports OR 8 I/O channels
PoEOptional five-port PSE; DC 48–55 V when enabledNo PoE
Cellular4G Cat.4 or 5G RedCap4G Cat.4 or 5G RedCap
Dimensions110 × 86 × 40 mm110 × 87 × 52 mm

Each group provides one serial port OR two same-type I/O channels. Options are selected when ordering.

View FCT-6300-F2B1 →

Documentation and project verification — FCT-6300-F5

Before ordering or wiring, confirm the exact model and configuration, interface pinout, optical or network compatibility, power input and installation conditions. Optional configurations are not interchangeable.

Browse FCTEL technical documents · Request the current model-specific datasheet and wiring diagram

Send a product inquiry

Tell us your application, quantity and preferred configuration.

We use your information only to respond to this inquiry.