Water Pump Station · Remote Monitoring
Water pump station example: 2 RS-485 + 4 AI. Fiber LAN joins the local site network; WAN / 4G provides remote connectivity. The PLC retains local control.
Model:FCT-6300-F2B1
Photos show the 4G version; RedCap antennas follow the ordered configuration.
Two copper ports, one fiber port, and four configurable serial / I/O groups
Connect industrial devices through two Fast Ethernet RJ45 ports, one 100 Mbps SFP LAN port and four shared serial / I/O groups. Choose 4G Cat.4 or 5G RedCap, with eSIM support and optional Wi-Fi.
FCT-6300-F2B1 connects industrial instruments and acquisition interfaces through one copper LAN, one copper WAN and one 100 Mbps SFP LAN port.
Choose interfaces and network options to generate the corresponding complete ordering model.
4 serial ports · 0 I/O channels
| FCT- | 6300- | F2B1 | Interface code + quantity | UW | UF / UR | -CN / -AU / -EU |
|---|---|---|---|---|---|---|
| Company + type | Series | 2 copper + 1 fiber port | For example D4, D2A4 | Optional Wi-Fi | Choose one cellular version | 4G: CN / AU / EU RedCap: CN / EU |
An interface letter is followed by its quantity: D4 = four RS-485 ports; D2A4 = two RS-485 ports + four current inputs. Wireless codes follow UW + UF / UR. Omit UW when Wi-Fi is not selected.
| NO | Item | Definition | |
|---|---|---|---|
| 1 | Company | FC = FCTELE | |
| 2 | Product type | T = industrial gateway | |
| 3 | Series | 6300 = 110 mm industrial DIN-rail series | |
| 4 | Port specification | Ethernet | F = Fast Ethernet copper; B = Fast Ethernet fiber. F2B1 = two Fast Ethernet RJ45 ports (one WAN + one LAN) + one 100 Mbps SFP LAN2 port. |
| Serial Ports | D = RS-485; R = RS-232; X = RS-422. | ||
| DI / DO | K = digital input (DI); J = digital output (DO). | ||
| AI / AO | A = current input; M = current output; V = voltage input; Y = voltage output. | ||
| 5 | Wireless configuration | UW = optional 2.4 GHz Wi-Fi; UF = 4G Cat.4; UR = 5G RedCap. Choose UF or UR. | |
| Other wireless codes | UL = LoRa; UX = Wi-Fi 6; UB = Wi-Fi 7; UO = 4G Cat.1; UG = full-featured 5G. These are general naming references, not confirmed options for this model. | ||
| 6 | eSIM / PoE | eSIM supported with operator provisioning. This gateway has no PoE and no -P model suffix. | |
| 7 | Regional suffix | Cat.4: -CN / -AU / -EU. RedCap: -CN / -EU. Place the regional suffix last; see the band tables. | |
| Example Ordering Model | Configuration Details |
|---|---|
| FCT-6300-F2B1D4UWUF-CN | 4 RS-485 + Wi-Fi + 4G Cat.4, China version |
| FCT-6300-F2B1D4UR-CN | 4 RS-485 + RedCap-CN, dual cellular antennas, no Wi-Fi |
| FCT-6300-F2B1D4UR-EU | 4 RS-485 + RedCap-EU, dual cellular antennas, no Wi-Fi |
| FCT-6300-F2B1D4UWUR-EU | 4 RS-485 + RedCap-EU + Wi-Fi, one cellular antenna |
| FCT-6300-F2B1D2A4UF-CN | 2 RS-485 + 4 current inputs + Cat.4, without Wi-Fi |
All examples have two copper ports, one fiber port, eSIM support and no PoE. RedCap offers dual cellular antennas without Wi-Fi OR one cellular antenna with Wi-Fi; assess site signal conditions for the latter. Every two same-type I/O channels replace one serial port.
Cloud service: an FCTELE monitoring platform is optional. Service charges and volume arrangements follow the commercial agreement. Video applications require a separate video platform.
Included accessories: cellular / Wi-Fi antennas follow the selected version. Optical transceivers, fiber, power supplies and mounting accessories follow the order list.
Configure each of the four groups as one serial port OR two same-type DI / DO / AI / AO channels: up to four serial ports OR eight I/O channels. RedCap offers dual cellular antennas without Wi-Fi, or one cellular antenna with Wi-Fi; see the ordering options.
Check interfaces and power first, then expand software, frequency bands and mounting dimensions.
| Communication interfaces | |
|---|---|
| LAN1 RJ45 | 1 x RJ45, 10/100 Mbps, auto-negotiated full / half duplex |
| WAN RJ45 | 1 x RJ45, 10/100 Mbps, auto-negotiated full / half duplex |
| LAN2 SFP | 1 × SFP, 100 Mbps fiber Ethernet, used as LAN; transceiver selected for the configuration |
| Ethernet features | Auto-MDI/MDIX; 4,096-entry MAC address table |
| Serial / I/O | 4 ordered RS-232 / RS-422 / RS-485 ports. Each serial resource can be replaced by 2 DI / 2 DO / 2 AI / 2 AO of the same type: up to 8 I/O channels. |
| SIM / eSIM | 2 physical SIM slots; dual-SIM single standby; eSIM supported |
| Antenna interfaces | 4G: cellular + Wi-Fi. RedCap: dual cellular without Wi-Fi, or single cellular + Wi-Fi |
| Power connector | 4-position pluggable terminal, 5.08 mm pitch |
Serial rate: 300–150000 bps. RS-232: RXD / TXD / GND; two-wire RS-485: A / B / GND.
RS-422 and four-wire RS-485: TxD+ / TxD- / RxD+ / RxD- / GND. Interface type is selected when ordering.
| Mechanical and environmental specifications | |
|---|---|
| Dimensions | 110 × 87 × 52 mm |
| Enclosure & cooling | Aluminum-alloy enclosure; fanless cooling |
| Ingress protection | IP40 |
| Mounting | 35 mm DIN rail or wall mounting |
| Weight | 0.55 kg per unit |
| Operating temperature | 4G: -40 to +85 degC; see the RedCap temperature note |
| Storage temperature | -40 to +85 degC |
| Operating humidity | 0-95% RH, non-condensing |
| Wireless LAN | |
|---|---|
| Wireless LAN | 2.4 GHz, IEEE 802.11b/g/n, single antenna; theoretical wireless rate up to 150 Mbps |
Wireless rates are theoretical peaks; actual application throughput depends on the network, antennas and load. Ethernet ports operate at 10/100 Mbps.
| Serial Ports | I/O | Example Configuration |
|---|---|---|
| 4 channels | 0 channels | D4: 4 RS-485 |
| 3 channels | 2 channels | D3K2: 3 RS-485 + 2 DI |
| 2 channels | 4 channels | D2A4: 2 RS-485 + 4 current inputs |
| 1 channel | 6 channels | 1 serial port + three groups of 2 I/O channels |
| 0 channels | 8 channels | Four I/O groups; 2 channels per group, with the type selected for each group |
Four resource groups: choose one serial port OR two same-type I/O channels per group.
| Power | |
|---|---|
| Gateway power input | Dual redundant DC 9–70 V inputs |
| Protection | Overload and reverse-polarity protection |
| Gateway consumption | <3 W |
| Acquisition interface options | |
|---|---|
| Serial / I/O relationship | Every two same-type acquisition channels replace one serial port; four shared groups, up to 8 I/O channels |
| Allowed combinations | Each group: one serial port OR 2 DI / 2 DO / 2 AI / 2 AO. Combine four groups without allocating a resource twice |
| Digital input (DI) | Dry contact or NPN / PNP transistor input |
| Digital output (DO) | 24 V DC applications; switching current: dry contact 0.5 A, MOS / optical MOS 0.12 A |
| Analog characteristics | 12-bit resolution; sampling rate 1,000 samples/s |
| Analog input ranges | 0-20 mA, 4-20 mA, 0-5 V, 0-10 V, -5 to +5 V |
Choose 4 serial ports, 3 serial + 2 I/O, 2 serial + 4 I/O, 1 serial + 6 I/O, or 8 I/O. Confirm signal types and analog ranges with the order.
RedCap temperature: cellular-module operation -35 °C to +75 °C, with an extended module range of -40 °C to +85 °C. Confirm extension conditions and complete-device applicability for the order.
The SFP is LAN2. Match single-mode / multimode, wavelength, distance and connector to the peer device. This gateway has no PoE: external devices need separate power. Photos show the 4G version; RedCap antennas follow the order.
| Cellular versions | |
|---|---|
| 4G Cat.4 | UF; LTE FDD / TDD, without carrier aggregation |
| 5G RedCap | UR; Release 17, 5G SA / LTE Cat.4; see regional bands |
| Configuration | Application Priority | Ordering Code |
|---|---|---|
| 2 cellular antennas, without Wi-Fi | Prioritize cellular reception | UR (dual cellular) |
| 1 cellular antenna + 2.4 GHz Wi-Fi | Wi-Fi required alongside cellular | UWUR (single cellular) |
A single cellular antenna may affect reception, throughput and connection stability in weak-signal or multipath conditions. Assess the effect through on-site testing.
| Cellular versions | Supported Network | Module Theoretical Downlink / Uplink |
|---|---|---|
| 4G Cat.4 | LTE FDD / TDD | FDD: 150 / 50 Mbps; TDD: 130 / 30 Mbps |
| 5G RedCap | 5G SA / LTE Cat.4 | SA 64QAM and LTE: 150 / 50 Mbps; optional SA 256QAM: 226 / 120 Mbps |
Theoretical peaks depend on module configuration and network support. Traffic on an individual Fast Ethernet port is limited by its 100 Mbps rate and protocol overhead.
Operating system: OpenWrt
| Network and data functions | |
|---|---|
| Wired access | Static IP, DHCP, PPPoE |
| Cellular access | Cellular dial-up; APN / VPDN private networks |
| Dial-up authentication | CHAP, PAP, MS-CHAP, MS-CHAPv2, or no authentication |
| Link backup | Wired / cellular backup, wired recovery detection and dual-SIM failover |
| Connection maintenance | Heartbeat and online detection, reconnection, watchdog and system monitoring |
| Routing | NAT, PAT, DMZ, port mapping, virtual server, DDNS |
| Firewall | SPI stateful packet inspection and iptables firewall configuration |
| VPN compatibility | PPTP / L2TP; configurable redial intervals and attempts |
| Device management | Web management / upgrade; SMS connection control and status notification |
| Wi-Fi management | Wireless repeater, WDS bridging, guest network, scheduling, regional channels and transmit-power adjustment |
| Serial tunneling | TCP / UDP Server, Client |
| Protocol conversion | Modbus RTU to Modbus TCP |
| MQTT data | Multi-topic publish / subscribe, MQTT tunneling, Modbus-to-JSON conversion, incoming JSON parsing and periodic reporting |
Dual SIM is single standby: two cellular connections are not established simultaneously. eSIM requires operator provisioning. Link switching and service recovery depend on the network and configuration.
| Model / Region | -CN | -AU | -EU |
|---|---|---|---|
| China / India | Latin America / Australia / New Zealand | EMEA / Southeast Asia | |
| LTE-FDD | B1/3/5/8 | B1/2/3/4/5/ 7/8/28/66 | B1/3/5/7/8/ 20/28 |
| LTE-TDD | B34/38/39/ 40/41 | B40 | B38/40/41 |
| WCDMA | B1/5/8 | B1/2/4/5/8 | B1/5/8 |
| GSM | EGSM900 / DCS1800 | GSM850 / EGSM900 / DCS1800 / PCS1900 | EGSM900 / DCS1800 |
| Model / Region | -CN | -EU |
|---|---|---|
| China | EMEA / Southeast Asia Australia / New Zealand | |
| 5G NR SA | n1/3/5/8/28/ 40/41/78/79 | n1/3/5/7/8/20/ 28/38/40/41/77/78 |
| LTE-FDD | B1/3/5/8 | B1/3/5/7/8/20/28 |
| LTE-TDD | B34/38/39/40/41 | B38/40/41/42/43 |
Regional suffixes depend on the cellular version: CN / AU / EU for Cat.4; CN / EU for RedCap. Select EU for RedCap projects in Australia and New Zealand. EMEA means Europe, the Middle East and Africa. Verify operator bands and site coverage.
Overall dimensions: 110 × 87 × 52 mm. Dimensions are in mm; the drawing includes five views, wall-mount holes and DIN-rail mounting.
Each application is shown separately. Click an image to enlarge it on this page.
Water pump station example: 2 RS-485 + 4 AI. Fiber LAN joins the local site network; WAN / 4G provides remote connectivity. The PLC retains local control.
Industrial automation example: 2 serial ports + 2 DI + 2 DO. Collect equipment status; connect DO loads through suitable external relays. The PLC / safety system retains production control.
Energy monitoring example: four RS-485 ports collect meter and environmental-instrument data. The fiber LAN connects the local aggregation network; WAN / cellular links reach the remote business platform.
Check interfaces, power and site network conditions, then confirm the complete ordering model.
One RJ45 WAN, one RJ45 LAN1 and one SFP LAN2. RJ45 ports support 10/100 Mbps; the fiber port is 100 Mbps Ethernet used as LAN. Match transceiver mode, wavelength, distance and connector to the peer device and ordered configuration.
Reference: product specification Interfaces, Hardware & electrical · Check Communication Interfaces →
Serial and I/O share four resource groups. Each group provides one serial port OR two same-type DI, DO, AI or AO channels. Valid totals are 4 serial, 3 serial + 2 I/O, 2 serial + 4 I/O, 1 serial + 6 I/O, or 8 I/O. Do not add both maximum counts together. Signal types and ranges follow the order.
Reference: product specification Interfaces, Hardware & electrical · Check Shared Resources →
Use interface code D2A4: D means RS-485 and A means current input. FCT-6300-F2B1D2A4UF-CN specifies two RS-485 ports, four current inputs and China-version 4G Cat.4, without Wi-Fi. Confirm any other cellular version, region and analog ranges when ordering.
Reference: product specification Hardware & electrical, Ordering & regional bands · Check Complete Model Examples →
RedCap offers two configurations: UR has dual cellular antennas without Wi-Fi; UWUR has one cellular antenna and 2.4 GHz Wi-Fi. Choose UWUR when Wi-Fi is needed and assess the site signal. Verify reception, throughput and stability with one cellular antenna in weak-signal or multipath conditions.
Reference: product specification Hardware & electrical, Ordering & regional bands · Check Antenna Options →
Cat.4 uses -CN, -AU or -EU. RedCap uses -CN or -EU. For Australia and New Zealand, this specification lists Cat.4 -AU and RedCap -EU. Always check the frequency table, operator network and site coverage; a regional label does not replace band verification.
Reference: product specification Ordering & regional bands · Check Regions & Bands →
This model has no PoE and no -P suffix. It uses dual redundant DC 9–70 V inputs, overload and reverse-polarity protection, and has specified device consumption below 3 W. External instruments and other devices need separate power. Power supplies and accessories follow the order list.
Reference: product specification Hardware & electrical, Ordering & regional bands · Check Power & Accessories →
Two physical SIM slots support dual-SIM single standby, with only one cellular connection active at a time. The specification lists dual-SIM failover, wired / cellular backup and wired-link recovery detection. Switching and service recovery depend on the network and configuration. eSIM requires operator provisioning.
Reference: product specification Interfaces, Hardware & electrical, Networking & dimensions · Check Networking & Maintenance →
The specification lists Modbus RTU-to-TCP conversion, multi-topic MQTT publish / subscribe, transparent MQTT transport, Modbus-to-JSON conversion, incoming JSON parsing and scheduled reporting. Check instrument protocols, registers, platform topics and data formats, then validate them with the delivered firmware.
Reference: product specification Networking & dimensions · Check Network & Data Functions →
The 4G operating range is -40 °C to +85 °C. The RedCap cellular-module range is -35 °C to +75 °C, with an extended module range of -40 °C to +85 °C. Confirm extension conditions and complete-device applicability with the order; module extension figures are not a complete-device temperature guarantee.
Reference: product specification Hardware & electrical · Check Temperature Conditions →
The enclosure measures 110 × 87 × 52 mm and supports 35 mm DIN rail or wall mounting. Allow extra space for terminals, antennas, ventilation and fiber bend radius. Check mounting holes and structure against the five-view drawing and interface / mounting illustrations.
Reference: product specification Interfaces, Networking & dimensions · Check Dimensions & Mounting →
Use these references to check the FCT-6300-F2B1 configuration. Cellular version, serial / I/O allocation, optical transceivers and included accessories follow the selected order.
Specification · Interfaces
Four terminal groups, WAN / LAN roles, DC power, SIM slots, antennas, DIN-rail clip and wall-mount holes.
Specification · Hardware
Shared serial / I/O allocation, power, temperature, analog ranges and RedCap antenna options.
Specification · Networking
Five-view drawing and mounting details; OpenWrt, network maintenance, Modbus and MQTT features.
Specification · Ordering
Cat.4 / RedCap regional suffixes, cellular bands, interface codes and complete example models.
The four product views show the 4G version. Check RedCap antenna arrangements and delivered interfaces against the selected order. Use the interface and dimension drawings to plan mounting.
The water, factory and energy graphics illustrate typical applications and device / network roles. Project-specific equipment, platforms and validation requirements follow the application.
If the project requires temperature, EMC or continuous-operation test records, state the applicable standard, conditions and configuration in your inquiry. Technical staff can check the corresponding documentation and scope. Validate wiring and software settings against the delivered firmware, instrument protocols and platform requirements.
Submit Project Requirements →These guides explain general principles and commissioning methods. Check model-specific functions and configuration steps against the product specification and delivered firmware.
Distinguish byte transport from message conversion, then match host and instrument protocols.
Serial Device Servers vs. Modbus Gateways: Transport, Conversion and Selection
Check the physical interface, serial settings, network addressing and data path step by step.
Serial Device Server Setup: Settings, Loopback, Virtual COM and Acceptance Testing
Define repeatable acceptance checks for recovery, application data and site conditions.
Choosing a Serial Device Server: Interfaces, Buffers, Flow Control and Recovery
English Product Specification PDF
Before ordering or wiring, confirm the exact model and configuration, interface pinout, optical or network compatibility, power input and installation conditions. Optional configurations are not interchangeable.
Browse FCTEL technical documents · Request the current model-specific datasheet and wiring diagram
Share your devices, interfaces or quantity—our team will help you choose a suitable solution.
We use your information only to respond to this inquiry.