How to Tell RS232, RS485, Modbus and HART Apart: Understanding Electrical Interfaces and Data Rules in Layers
Identify the electrical and protocol layers before wiring RS-232 devices.
Identify the supply and Port 1 at the left and Ports 2 and 3 at the right. Cross-connect TXD and RXD to the other device.
Seat and lock the spring clip on a 35 mm DIN rail. Leave room to wire and service the terminals.
| Interface | Markings | Connection |
|---|---|---|
| Hub Port 1 | T1 / R1 / G1 | Left inner row. Connect the shared slave or PLC master according to operating mode. |
| Distribution Port 2 | T2 / R2 / G2 | Right inner row. Connect the first master or slave according to operating mode. |
| Distribution Port 3 | T3 / R3 / G3 | Right outer row. Connect the second master or slave according to operating mode. |
| DC supply | V+ / V− / SPD | Left outer row. Apply 9–70 V DC to V+ and V−. Use SPD according to the delivered wiring guide. |
| Hub terminal | Other device | Connection |
|---|---|---|
| Tn (TXD) | RXD | Transmits to the other device. |
| Rn (RXD) | TXD | Receives from the other device. |
| Gn (GND) | GND | Connect the corresponding signal ground. Keep port grounds separate. |
Side profile 115 × 100 mm, thickness 17 mm, approximately 0.15 kg. Leave space for terminal wiring.
| Item | Specification |
|---|---|
| Interface | Three EIA/TIA-232 (ITU-T V.28) channels: one hub port and two isolated distribution ports. |
| Buffering | Up to 10 KB of buffering with frame recognition and request/response coordination. |
| Modes | Default two-master/one-slave mode. The software can switch to one-master/two-slave mode. |
| Rate and framing | 1,200 to 115,200 bps per port. Default 9,600 bps, no parity, 8 data bits and 1 stop bit. |
| Status | PWR/D1, D2 and D3 show power and port activity. See the device markings. |
| Item | Rating | Conditions |
|---|---|---|
| Serial ports | 6 kV surge per port | Three-stage protection against induced and switching transients. |
| Power input | 6 kV surge | Overcurrent and reverse-polarity protection. |
| Signal and power isolation | 3 kV per channel | Optocouplers and isolated DC–DC supply. G1, G2, G3 and supply ground remain separate. |
| AC misconnection test | 220 / 380 V AC | Fault isolation protects other equipment on the isolated side under the documented test conditions. |
Surge test: GB/T 17626.5 (IEC 61000-4-5), 10/700 μs open-circuit waveform, 6 kV peak and 40 Ω source impedance.
| Item | Specification |
|---|---|
| DC input | 9–70 V DC, <1 W. Three-position, 5.08 mm pitch terminal. |
| Mounting | 35 mm DIN rail, fanless. Side view 115 × 100 mm, thickness 17 mm, approximately 0.15 kg. |
| Environment | Operating and storage −40 to +85 °C. Operating humidity 0–95% RH, non-condensing. |
| Reliability | MTBF >200,000 hours, 100% burn-in testing and industrial Level 4 EMC per datasheet. |
Connect the masters to Ports 2 and 3 and the shared slave to Port 1. Cross-connect TXD and RXD on each connection.
After switching modes in software, connect the PLC master to Port 1 and one slave to each distribution port. Use the appropriate protocol and polling arrangement.
Confirm the operating mode, per-port serial settings, DC supply and RS-232 cables or installation accessories.
| Ordering Model | Configuration |
|---|---|
| FCC-1210-R1R2M | One RS-232 hub port and two isolated distribution ports, up to 10 KB of buffering, 9–70 V DC and 35 mm DIN-rail mounting. |
Connect the two masters to Ports 2 and 3, and the shared RS-232 slave to Port 1.
Switch the hub mode in software. Connect the master to Port 1, and the slaves to Ports 2 and 3.
Connect the hub TXD (Tn) to the receiver RXD, and the hub RXD (Rn) to the other device TXD. Connect signal GND to the corresponding Gn.
G1, G2 and G3 are separate references, isolated from each other and from supply negative. Use the correct ground for each port.
The serial default is 9,600 bps, 8 data bits, no parity and 1 stop bit. Each port can be configured separately. Use 9–70 V DC.
Identify the electrical and protocol layers before wiring RS-232 devices.
Check TXD, RXD and signal ground, and verify the mapping between serial devices and ports.
Check physical connections and confirm that the attached software uses compatible settings.
Tell us your application, quantity and preferred configuration.