Compact Lipstick-Size Serial Device Servers: Installation and Optional PD Power
Check cabinet clearance, terminal supply and the optional PD connection.
Photos show the A2 current-input version. See Ordering for the six signal configurations.
The front shows RX, TX, LOK and PWR. Follow the supplied instructions for Reload. The Ethernet symbol marks the socket at the bottom.
The top connector has two DC terminals and three serial terminals. Check the ordered version, the delivery wiring and the terminal markings before connecting.
Connect the bottom RJ45 for 10/100 Mbps Ethernet. On the -PD version, the same cable can deliver power from a compatible IEEE 802.3af/at PSE.
The rear clip fits a 35 mm DIN rail. The wall-bracket drawing below shows the mounting holes.
| Group | Marking | Connection |
|---|---|---|
| DC input | + / − | Apply 9–50 V DC at the top terminal pair, observing polarity. |
| F1D1 serial | A / B / GND | One two-wire RS-485 port, A (TX+), B (TX−) and GND. |
| F1R1 serial | TXD / RXD / GND | One RS-232 port. Check TXD and RXD direction against the connected device. |
| Ethernet | Bottom RJ45 | One Fast Ethernet data port. Optional -PD model also accepts power from compatible PSE over this port. |
| Status & maintenance | RX / TX / LOK / PWR / Reload | Check indicators and follow the supplied guide for Reload. |
| Item | Specification |
|---|---|
| Processor | ARM Cortex-M4 at 240 MHz. |
| Ethernet | One 10/100BASE-T(X) RJ45, full/half-duplex auto-negotiation and Auto-MDI/MDIX. |
| F1D1 serial | One two-wire RS-485 channel. 300–921,600 bps; supports custom rates. |
| F1R1 serial | One RS-232 channel. 300–256,000 bps; supports custom rates. |
| Top terminal | Two power and three serial positions. 2.54 mm screwless terminals. |
| Standard power | DC 9–50 V, under 2 W. Overload and reverse-polarity protection. |
| Optional PD input | IEEE 802.3af/at powered-device option. Receives power and data from compatible PSE over RJ45. |
| Housing and mounting | Fanless steel case. 24 × 80 × 20 mm, 68.9 g. 35 mm DIN rail or wall mount. |
| Environment | Operating and storage −40 to +85 °C, 0–95% RH non-condensing. MTBF over 100,000 hours. |
| Item | Function |
|---|---|
| Protocols | TCP, UDP, ARP, ICMP, HTTP, DNS, DHCP, SNMP and MQTT. |
| Operating modes | TCP Server/Client, UDP Server/Client. Up to four TCP or UDP sessions per serial port. |
| Conversion | Modbus RTU to Modbus TCP, MQTT transparent transmission and Modbus-to-JSON data packets. |
| Access | Virtual COM and TCP/IP sockets, serial framing, gateway and routed-network communication. |
| Monitoring | Serial status and parameter monitoring. Automatic reconnection after interruption. |
| Management | Web, Windows tools, serial configuration, access control, SNMP and local or remote firmware upgrades. |
Several sessions share the same serial channel. Coordinate requests from the host and set topic, message and register parameters per project.
| Interface | Rating | Condition |
|---|---|---|
| DC terminal input | 6 kV surge protection | Overload and reverse-polarity protection. |
| RS-232 / RS-485 | 6 kV open-circuit peak | Surge protection on the selected serial interface. |
GB/T 17626.5 / IEC 61000-4-5 surge immunity test. Open-circuit waveform 10/700 μs, 40 Ω source impedance.
Connect the RS-485 instrument to an F1D1. With a compatible Modbus RTU instrument, a Modbus TCP client can read the data over Ethernet. Power the instrument separately.
Use one F1R1 at each end. Match the serial framing and bit rate. Point the TCP Client to the reachable IP address and port of the TCP Server.
Choose the serial standard, power option, mounting hardware and cables. For a -PD model, confirm compatible PSE and its power budget. Attached instruments use their own power supply.
| Full Model Code | Serial port | Power configuration |
|---|---|---|
| FCT-1100-F1D1 | 1 × two-wire RS-485 | DC 9–50 V terminal input. |
| FCT-1100-F1R1 | 1 × RS-232 | DC 9–50 V terminal input. |
| FCT-1100-F1D1-PD | 1 × two-wire RS-485 | Optional IEEE 802.3af/at PD input over RJ45. |
| FCT-1100-F1R1-PD | 1 × RS-232 | Optional IEEE 802.3af/at PD input over RJ45. |
| Segment | Definition |
|---|---|
| FCT-1100 | Compact industrial serial server series. |
| F1 | One 10/100 Mbps RJ45 Ethernet port. |
| D1 / R1 | One two-wire RS-485 / one RS-232 port. |
| -PD | Optional power over RJ45 from compatible PSE. |
Choose FCT-1100-F1D1 for a two-wire RS-485 device. For RS-232, choose FCT-1100-F1R1. Each unit has one serial port.
F1D1 supports 300–921,600 bps. F1R1 supports 300–256,000 bps. Custom rates are available within the supported range.
Order the matching -PD variant and use an IEEE 802.3af/at-compatible PSE. The network cable carries data and supplies power to the server.
The PD input powers the serial server. Use the appropriate independent supply for the connected instrument.
Up to four TCP or UDP sessions. Coordinate concurrent requests at the host to avoid conflicting requests to one instrument.
Check cabinet clearance, terminal supply and the optional PD connection.
Check wiring, network access and polling before commissioning.
Check how TCP requests are mapped to RTU and how polling affects response times.
Tell us your application, quantity and preferred configuration.