+8618758069661 [email protected]

Compact RS-485 or RS-232 Serial Server

Model:FCT-1100-F1D1 / FCT-1100-F1R1
1,602 +0

Connect one serial device to Ethernet in a narrow cabinet

  • Choose the serial interface to match the deviceF1D1 has one two-wire RS-485 port. F1R1 has one RS-232 port. Both use one 10/100 Mbps RJ45 Ethernet port.
  • Connect field devices to existing softwareUse virtual COM, TCP or UDP sessions, Modbus RTU-to-TCP conversion, MQTT transparent transmission or Modbus-to-JSON.
  • Choose terminal power or optional PDUse 9–50 V DC at the top terminals, or order a -PD version to receive power and data through RJ45 from a compatible PSE.

Photos show the A2 current-input version. See Ordering for the six signal configurations.

Purpose & Applications

  • Bring a single serial instrument or controller onto an Ethernet network. Select the F1D1 or F1R1 hardware version according to its electrical interface.
  • Use Modbus RTU-to-TCP conversion, MQTT transparent transmission, Modbus-to-JSON or serial transport for the host software.
  • Fit the 24 × 80 × 20 mm fanless steel housing on a 35 mm DIN rail or wall bracket. Choose the power version to suit the cabinet.

Key Features

Per-port settings
Set baud rate, parity, data bits and stop bits per port. Supports configuration software and Modbus RTU settings.
Branch isolation
The five RS-485 grounds and supply ground are isolated. Each distribution port exposes only A/B.
Protection
6 kV surge rating per RS-485 channel and for the power input.
Panel status
PWR/D0 reports power and hub activity. D1–D4 report the corresponding distribution ports.

Terminal and Signal Reference
GroupMarkingConnection
DC input+ / −Apply 9–50 V DC at the top terminal pair, observing polarity.
F1D1 serialA / B / GNDOne two-wire RS-485 port, A (TX+), B (TX−) and GND.
F1R1 serialTXD / RXD / GNDOne RS-232 port. Check TXD and RXD direction against the connected device.
EthernetBottom RJ45One Fast Ethernet data port. Optional -PD model also accepts power from compatible PSE over this port.
Status & maintenanceRX / TX / LOK / PWR / ReloadCheck indicators and follow the supplied guide for Reload.
Dimensions & Mounting
Body and DIN rail · 24 × 80 × 20 mm, 68.9 g
Wall bracket · 40 × 20 mm hole spacing

Hardware, Power & Environment
ItemSpecification
ProcessorARM Cortex-M4 at 240 MHz.
EthernetOne 10/100BASE-T(X) RJ45, full/half-duplex auto-negotiation and Auto-MDI/MDIX.
F1D1 serialOne two-wire RS-485 channel. 300–921,600 bps; supports custom rates.
F1R1 serialOne RS-232 channel. 300–256,000 bps; supports custom rates.
Top terminalTwo power and three serial positions. 2.54 mm screwless terminals.
Standard powerDC 9–50 V, under 2 W. Overload and reverse-polarity protection.
Optional PD inputIEEE 802.3af/at powered-device option. Receives power and data from compatible PSE over RJ45.
Housing and mountingFanless steel case. 24 × 80 × 20 mm, 68.9 g. 35 mm DIN rail or wall mount.
EnvironmentOperating and storage −40 to +85 °C, 0–95% RH non-condensing. MTBF over 100,000 hours.
Communications & Management
ItemFunction
ProtocolsTCP, UDP, ARP, ICMP, HTTP, DNS, DHCP, SNMP and MQTT.
Operating modesTCP Server/Client, UDP Server/Client. Up to four TCP or UDP sessions per serial port.
ConversionModbus RTU to Modbus TCP, MQTT transparent transmission and Modbus-to-JSON data packets.
AccessVirtual COM and TCP/IP sockets, serial framing, gateway and routed-network communication.
MonitoringSerial status and parameter monitoring. Automatic reconnection after interruption.
ManagementWeb, Windows tools, serial configuration, access control, SNMP and local or remote firmware upgrades.

Several sessions share the same serial channel. Coordinate requests from the host and set topic, message and register parameters per project.

Port Protection
InterfaceRatingCondition
DC terminal input6 kV surge protectionOverload and reverse-polarity protection.
RS-232 / RS-4856 kV open-circuit peakSurge protection on the selected serial interface.

GB/T 17626.5 / IEC 61000-4-5 surge immunity test. Open-circuit waveform 10/700 μs, 40 Ω source impedance.

Read a building meter over Ethernet

Connect the RS-485 instrument to an F1D1. With a compatible Modbus RTU instrument, a Modbus TCP client can read the data over Ethernet. Power the instrument separately.

Link two RS-232 devices over an IP network

Use one F1R1 at each end. Match the serial framing and bit rate. Point the TCP Client to the reachable IP address and port of the TCP Server.

Choose the serial standard, power option, mounting hardware and cables. For a -PD model, confirm compatible PSE and its power budget. Attached instruments use their own power supply.

FCT-1100-F1D1Request a Quote
Ordering Models
Full Model CodeSerial portPower configuration
FCT-1100-F1D11 × two-wire RS-485DC 9–50 V terminal input.
FCT-1100-F1R11 × RS-232DC 9–50 V terminal input.
FCT-1100-F1D1-PD1 × two-wire RS-485Optional IEEE 802.3af/at PD input over RJ45.
FCT-1100-F1R1-PD1 × RS-232Optional IEEE 802.3af/at PD input over RJ45.
Model Code
SegmentDefinition
FCT-1100Compact industrial serial server series.
F1One 10/100 Mbps RJ45 Ethernet port.
D1 / R1One two-wire RS-485 / one RS-232 port.
-PDOptional power over RJ45 from compatible PSE.

Serial interfaces

2 questions
01QWhich model should I order for RS-485?
A

Choose FCT-1100-F1D1 for a two-wire RS-485 device. For RS-232, choose FCT-1100-F1R1. Each unit has one serial port.

02QWhat baud rates can I use?
A

F1D1 supports 300–921,600 bps. F1R1 supports 300–256,000 bps. Custom rates are available within the supported range.

Ethernet and power

2 questions
03QCan I power the server through Ethernet?
A

Order the matching -PD variant and use an IEEE 802.3af/at-compatible PSE. The network cable carries data and supplies power to the server.

04QCan the -PD version power the attached instrument?
A

The PD input powers the serial server. Use the appropriate independent supply for the connected instrument.

Network use

1 question
05QHow many network sessions can share the serial port?
A

Up to four TCP or UDP sessions. Coordinate concurrent requests at the host to avoid conflicting requests to one instrument.

Compare Serial and Power Configurations

Full Model CodeSerial portPower configuration
FCT-1100-F1D11 × two-wire RS-485DC 9–50 V terminal input.
FCT-1100-F1R11 × RS-232DC 9–50 V terminal input.
FCT-1100-F1D1-PD1 × two-wire RS-485Optional IEEE 802.3af/at PD input over RJ45.
FCT-1100-F1R1-PD1 × RS-232Optional IEEE 802.3af/at PD input over RJ45.

Send a product inquiry

Tell us your application, quantity and preferred configuration.

We use your information only to respond to this inquiry.