Analog Fiber Link Troubleshooting: Readings, Errors and Hold
Trace power, loop continuity, receiving load and scaling in a 4–20 mA installation.
The output banks are at the top. The input and sensor feed share a bank near the bottom, with the separate 24 V DC supply on the lowest bank.
The side label identifies the input, four isolated output loops and supply. Follow the terminal-side markings when connecting the wires.
| Interface | Markings | Connection |
|---|---|---|
| Outputs 3 and 4 | O3+ / G3 / O4+ / G4 | Top row. Connect receivers 3 and 4 to their respective positive and return terminals. |
| Outputs 1 and 2 | O1+ / G1 / O2+ / G2 | Second row. Connect receivers 1 and 2 to their respective positive and return terminals. |
| Input and sensor feed | IN+ / G / 24V / G | One 4–20 mA input. Use the sensor feed as shown for the transmitter wiring. |
| Separate power | V+ / V− / V− / NC | Connect a separate 24 V DC supply. Leave NC unconnected. |
| Connection Type | Wiring |
|---|---|
| Two-wire transmitter | Connect input-side 24V to transmitter VCC and the transmitter signal to IN+. Leave both input G terminals unconnected. |
| Three-wire transmitter | Connect 24V and G to transmitter VCC and GND, and the transmitter signal to IN+. |
| Four-wire transmitter | Connect 24V and G to transmitter VCC and power GND, signal GND to input G, and the transmitter signal to IN+. |
| Four output loops | Connect each On+ and Gn to the corresponding receiver + and − terminals (n = 1–4). Match each receiver to 4–20 mA. |
Keep the input and output references and the device supply negative separate. Check sensor-feed capacity against the transmitter load.
101 × 114 × 23 mm. Refer to the six-view drawing for enclosure and mounting clearances.
| Item | Specification |
|---|---|
| Signal | One isolated 4–20 mA input and four isolated 4–20 mA outputs. |
| Sampling rate | 2,000 samples/s |
| Latency | <0.1 ms |
| Maximum load | 600 Ω per output |
| Input resistance | 125 Ω |
| Accuracy | 0.1% at room temperature |
| Item | Specification |
|---|---|
| Supply | Separate 24 V DC supply, 50 mA maximum at 24 V. |
| Isolation method | Transformer isolation. The input, four output loops and supply have separate references. |
| Dielectric withstand | At least 1,500 V DC for one minute between input/output, input/power and output/power. |
| Analog protection | 6 kV per analog channel against induced transients, per datasheet. |
| Power protection | 6 kV at the power input. Includes overload and reverse-polarity protection. |
| EMC | Industrial EMC level 4 requirements per datasheet. |
| Item | Specification |
|---|---|
| Operating and storage | −40 to +85 °C |
| Humidity | 0–95% RH, non-condensing |
| Cooling and screening | Fanless, 100% burn-in testing. MTBF >100,000 hours. |
| Installation and dimensions | 35 mm DIN rail or wall mounting. Enclosure 101 × 114 × 23 mm. |
Connect the two-wire transmitter to input-side 24V and IN+. Leave both input G terminals open. Each receiving instrument uses its own 4–20 mA output and return.
Confirm the transmitter wiring, the load on each of the four receivers and the mounting method. FC-A4JM has one input and four isolated outputs.
| Ordering Model | Configuration |
|---|---|
| FC-A4JM | One isolated 4–20 mA input, four isolated 4–20 mA outputs and a dedicated 24 V DC power terminal. |
Yes. One 4–20 mA input feeds four isolated outputs. Each output has a separate return terminal.
Connect input-side 24V to transmitter VCC and the transmitter signal to IN+. Leave both input G terminals unconnected.
Keep G1 through G4 separate from each other, input G and supply V− to maintain the isolated loop references.
The specified maximum is 600 Ω for each output. Check the load on each receiver loop.
Yes. Apply a separate 24 V DC supply to the marked V+ and V− terminals. Leave NC unconnected.
Trace power, loop continuity, receiving load and scaling in a 4–20 mA installation.
Check analog input and output wiring, reference points and signal ranges.

Understand analog acquisition and choose the appropriate signal path.
Tell us your application, quantity and preferred configuration.