+8618758069661 [email protected]

2-Master Buffered RS-485 DIN-Rail Hub

Model:FCC-1210-D1D2M
2,954 +0

Coordinate RS-485 access to a shared instrument

  • Let two masters share one RS-485 deviceBuffered mode coordinates requests from masters on ports 2 and 3 to the shared slave on hub port 1.
  • Switch to one master and two branchesUse the configuration software to put the master on port 1 and its two RS-485 branches on ports 2 and 3.
  • Keep the three signal grounds separateEach port has an independent signal ground. The three port grounds and power ground are mutually isolated at 3 kV.

Purpose & Applications

  • Share one RS-485 instrument between two controllers. Connect the master stations to ports 2 and 3 and the shared slave to hub port 1.
  • Up to 10K bytes of buffering and frame recognition coordinate requests and replies. Set the transmission rate and frame format individually for each port.
  • Switch to standard hub mode when one master needs two branches. Connect the master to hub port 1 and the field devices to ports 2 and 3.

Key Features

Per-port settings
Set baud rate, parity, data bits and stop bits per port. Supports configuration software and Modbus RTU settings.
Branch isolation
The five RS-485 grounds and supply ground are isolated. Each distribution port exposes only A/B.
Protection
6 kV surge rating per RS-485 channel and for the power input.
Panel status
PWR/D0 reports power and hub activity. D1–D4 report the corresponding distribution ports.

Terminals & Wiring
InterfaceMarkingsConnection
Hub port 1A1 / B1 / G1Left inner row. Connect the shared slave in buffered mode or the master in standard hub mode.
Distribution port 2A2 / B2 / G2Right inner row. Connect master 1 in buffered mode or branch 1 in standard hub mode.
Distribution port 3A3 / B3 / G3Right outer row. Connect master 2 in buffered mode or branch 2 in standard hub mode.
Power and NCV+ / V− / NCLeft outer row. DC 9–50 V with marked polarity, or AC 7–36 V per the wiring guide. Leave NC unconnected.
IndicatorsPWR/D1, D2, D3Observe power and port activity on the front panel.
Dimensions & Mounting

Side profile: 115 × 100 mm. Front thickness: 17 mm. Approximate weight: 0.15 kg. Mounts on a 35 mm DIN rail.

Communication & Configuration
ItemSpecification
RS-485 interfaceThree two-wire EIA/TIA-485 channels. A (+), B (−) and independent signal ground on each port.
BufferingUp to 10K bytes with frame recognition and request/reply coordination.
Rate and frame format1,200–115,200 bps, configured separately per port. Default 9,600 bps, 8N1. Select the operating mode in the configuration software.
Bus loading and reachUp to 128 nodes per port and up to 2,200 m per segment at 9,600 bps. Actual distance depends on cable, speed and installation.
Filtering and terminationCommon-mode and differential filtering. Built-in 120 Ω termination. Follow the wiring instructions for the bus topology.
ModeHub port 1Distribution ports 2 and 3
Two masters / one slaveShared RS-485 slaveMaster 1 on port 2. Master 2 on port 3.
One master / two slave branchesRS-485 masterSeparate slave or bus segment on each distribution port.
Isolation & Surge Protection
ItemRatingConditions
RS-485 channels6 kV surge per channelThree-stage surge protection.
Power input6 kV surgeOvercurrent protection and DC reverse-polarity protection.
Port and power grounds3 kV isolationOptocoupler and DC–DC isolation. G1, G2, G3 and supply ground are isolated from each other.
AC misconnection fault220 / 380 V AC fault conditionIsolation can protect equipment on the other serial ports. The affected RS-485 port may be damaged. Operating input limits are given under Power & Environment.

RS-485 surge test: GB/T 17626.5 / IEC 61000-4-5, 10/700 μs open-circuit voltage waveform, 40 Ω source impedance.

Power & Environment
ItemSpecification
Supply and consumptionDC 9–50 V or AC 7–36 V. Total power under 1 W. Three-position, 5.08 mm-pitch supply terminal.
Mounting35 mm DIN rail with a fanless housing. Approx. 0.15 kg.
Environment−40 to +85 °C for operation and storage. 0–95% RH during operation, non-condensing.
ReliabilityMTBF above 200,000 hours. All units are burn-in tested. Industrial Level 4 EMC per V1.2.

Buffered mode: two masters share one slave

Connect the two masters to ports 2 and 3 and the shared slave to port 1. The diagram shows a 24 V DC supply example.

Standard hub mode: one master feeds two branches

Switch modes in the configuration software. Connect the PLC to port 1 and each RS-485 branch to its own distribution port.

Specify the desired mode, serial settings for each port, supply type and mounting accessories when ordering.

FCC-1210-D1D2MRequest a Quote
Ordering Model
Ordering ModelConfiguration
FCC-1210-D1D2MOne hub port, two isolated RS-485 distribution ports and up to 10K bytes of buffering. DC 9–50 V / AC 7–36 V. 35 mm DIN rail.
Model Code
SegmentDefinition
FCC / 1210Product prefix and modular DIN-rail series.
D1One RS-485 hub port.
D2MTwo RS-485 distribution ports with buffering.

Modes and port roles

2 questions
01QWhere do the masters and the shared slave connect?
A

In the default buffered mode, connect the masters to ports 2 and 3. Connect the shared slave to hub port 1 at A1/B1/G1.

02QHow do I use one master with two branches?
A

Switch to standard hub mode in the configuration software. Connect the master to port 1 and the two field branches to ports 2 and 3.

Configuration and wiring

2 questions
03QCan I use different serial settings on each port?
A

Yes. Set baud rate and frame format independently. Each port defaults to 9,600 bps, 8N1.

04QHow are the signal and supply grounds arranged?
A

G1, G2 and G3 are independent signal grounds and are mutually isolated from one another and the power ground. Follow the delivered wiring guide.

Power supply

1 question
05QWhat supply can I use?
A

Use DC 9–50 V with marked polarity, or AC 7–36 V according to the wiring guide. Leave NC open.

Operating Modes

ModeHub port 1Distribution ports 2 and 3
Two masters / one slaveShared RS-485 slaveMaster 1 on port 2. Master 2 on port 3.
One master / two slave branchesRS-485 masterSeparate slave or bus segment on each distribution port.

Send a product inquiry

Tell us your application, quantity and preferred configuration.

We use your information only to respond to this inquiry.