+8618758069661 [email protected]
Optical communication and industrial internet solutions

Optical Communication & Industrial Internet Solutions

EXPERT IN OPTICAL COMMUNICATION & INDUSTRIAL INTERNET SOLUTIONS

Industrial DIN-Rail Cellular Router

Model:FCT-6600-G4U1
3 +3

Connect field instruments to wired and cellular networks

  • Gigabit copper and 1G/2.5G fiberUse three Gigabit LAN ports, one Gigabit WAN and one SFP slot.
  • Eight shared serial or I/O groupsBuild up to eight serial ports, up to 16 I/O channels, or a mix.
  • Wi-Fi 6 and three cellular optionsSelect 4G Cat.4, 5G RedCap or full 5G. Dual SIM operates in single standby.

Where it fits

  • Field instrument monitoring Read meters and sensors over serial, Ethernet or cellular links.
  • Multiple network paths Use wired and cellular backup where equipment is spread across the site.
  • Industrial data integration Convert Modbus RTU to Modbus TCP and report data through MQTT or JSON.

What to specify

Terminal groups
Choose one serial port or two same-type I/O channels per group.
Cellular region
Check the local operator bands and select the correct modem and SIM or eSIM option.
Fiber and power
Confirm the SFP speed and optical link, and provide DC 9–70 V to the redundant inputs.

01Connectors and mounting
02Wiring and installation checks

Connect the 3 LAN, 1 WAN and SFP ports to the matching networks. Identify the delivered terminal group configuration before connecting serial lines or field signals.

The four-pin power connector has two redundant DC 9–70 V inputs. Use the marked chassis grounding point. Antenna count depends on the selected cellular version. The INIT/RST opening is on the power-side panel.

Mount the enclosure on a 35 mm DIN rail or on a wall. Reserve space for cables, antenna connectors and the optical fiber bend radius.

03Dimensions and installation clearance
163 × 132 mm. The front view marks 52 mm and the side view marks 55 mm. Approximate unit weight is 1.12 kg.

01Power, hardware and environment
ItemSpecification
PowerDual DC 9–70 V redundant inputs, internal isolation; supports polarity auto-detection, overload and reverse connection protection, and power surge protection. 4-pin 5.08 mm pluggable terminals.
Total Power Consumption<12 W.
ItemSpecification
Processor/memoryFour-core ARM Cortex-A53, 1.8 GHz, 256 MB DDR.
Ethernet port3 × LAN+1 × WAN, RJ45, 10/100/1000 Mbps adaptive, full/half-duplex, Auto MDI/MDIX. MAC address table capacity 4096.
Fiber Port1 × SFP optical Ethernet port, 1G/2.5G adaptive. Optional SFP optical modules at corresponding speeds; both ends' speed, wavelength, and fiber type must match.
Serial ports and I/OUp to 16 DI/DO/AI/AO channels, grouped in pairs of 2. Each group can be replaced by a single serial port, up to 8 channels, with group-based mixing supported.
Serial port communicationRS-232, RS-422, or RS-485 configured according to the selected protocol. 300–150,000 bps, line-speed non-blocking. Supports Modbus RTU to Modbus TCP.
Mechanical and EnvironmentalIP40, fanless, black anodized brushed aluminum enclosure. Operating/storage −40 to +85 °C; humidity 0–95% RH, non-condensing.
ReliabilityMTBF >100,000 hours.
02Acquisition and serial signals
ItemParametersTechnical Specifications
Digital input DIInput TypeSupports dry contact, NPN or PNP transistor wet contact, and active signals. Supports active reporting and input linkage.
Digital output DODry contactSignal relay, 30 VDC/2 A, up to 50 Hz, response <1.2 ms.
Wet contact/PulseOptical MOS relay, 245 VDC/0.12 A, output 0–VCC (local power supply voltage), response <0.6 ms.
Output surge protectionWet contact uses TVS and solid discharge tube; dry contact relay output lacks this protection.
Current input/outputRange0–20 mA (including 4–20 mA), configurable range; linked output control supported.
Resolution/Sampling12 bits, 20,000 times/s.
Delay/Normal temperature accuracy<0.1 ms, 0.2%.
Input resistance/Output load125 Ω/maximum 600 Ω.
Voltage input/outputRange0–10 V (including 0–5 V) or −5 to +5 V, configurable range; linked output control supported.
Resolution/Sampling12 bits, 20,000 times/s.
Delay/Normal temperature accuracy<1 ms, 0.2%.
Input resistance/Output load100 kΩ/maximum 600 Ω.
Analog sensorConnection MethodAI supports 2-line, 3-line, or 4-line sensors.
StandardSignalStandards
RS-232RXD, TXD, GNDEIA/TIA-232 (ITU-T V.28)
RS-422TxD+, TxD−, RxD+, RxD−EIA/TIA-422 (ITU-T V.11)
RS-485 four-wireTxD+, TxD−, RxD+, RxD−EIA/TIA-485
RS-485 two-wireA (TX+), B (TX−), GNDEIA/TIA-485
03Port surge protection
Interface or test itemRating / Test ConditionsProtection Notes
Power Interface6 kV (open-circuit peak)Reduces lightning induction and switch operation surge risks on power lines; supports overload protection, DC terminals support reverse connection protection.
Serial interface6 kV (open-circuit peak)RS-232/RS-422/RS-485 used as optional configuration, reducing lightning induction and switch operation surge risks on signal lines.
RJ45 Ethernet interface4 kV (open-circuit peak voltage)Reduces lightning induction and switch operation surge risks on network lines.

Surge test: GB/T 17626.5 (IEC 61000-4-5), open-circuit voltage waveform 10/700 μs, test source impedance 40 Ω.

04Networking and software
ItemFunction
Operating SystemOpenWrt.
Wired ConnectionStatic IP, DHCP, PPPoE. IP configured separately for LAN and WAN, with cross-network routing support.
Cellular AccessCellular dialing, supporting APN/VPDN private networks.
Dial authenticationCHAP, PAP, MS-CHAP, MS-CHAPv2, and no authentication.
Link FailoverBackup for wired and cellular links, wired recovery detection, and dual SIM failover.
Online MaintenanceHeartbeat and online detection, connection reset, watchdog, and system monitoring.
Routing functionNAT, PAT, DMZ, port mapping, virtual servers, and DDNS.
FirewallSPI status packet detection, iptables firewall configuration, and DDoS protection.
ItemFunction
VPN compatiblePPTP/L2TP, supports setting of retry interval and count.
Device ManagementWeb management and upgrade, SMS control, network connection and status notification. PHP local browsing and remote synchronization of local storage content.
Wi-Fi managementWireless relay, WDS bridging, guest network, time period control, regional channel and transmission power adjustment.
Serial port transparent transmissionRS-232/422/485; TCP/UDP Server, Client. Can be connected to configuration screen, PLC or external instrument for self-polling.
Protocol ConversionModbus RTU to Modbus TCP.
MQTT dataMulti-topic publishing/subscription, MQTT transparent transmission, Modbus to JSON, JSON parsing and scheduled reporting.
Cloud platformSupports integration with Huawei Cloud, Alibaba Cloud and Mobile Cloud.

Dual physical SIM uses single standby. Select the SIM and failover configuration for the supplied modem. The full-5G EA option can support eSIM with operator activation. The CNV configuration does not support eSIM.

05Wi-Fi 6 and cellular rates
ItemSpecification
2.4 GHzIEEE 802.11b/g/n/ax, 20/40 MHz, theoretical peak 573.5 Mbps.
5 GHzIEEE 802.11a/n/ac/ax, 20/40/80/160 MHz, theoretical peak 2400 Mbps.
Mode and antennaSupports AP and Client. 2 × 2 MIMO per band, total 4 antenna interfaces for two bands.
Item4G Cat.45G RedCapFull 5G
Selection CodeUFURUG
Standard3GPP Rel-9, LTE FDD/TDD; no carrier aggregation3GPP Rel-17, NR SA; LTE Cat.4 fallbackSub-6 GHz, NR SA/NSA, LTE/WCDMA; EA: Rel-15; CNV: Rel-15, new features optional for Rel-16
Theoretical down/upFDD 150/50 Mbps; TDD 130/30 MbpsNR SA 226/120 Mbps; LTE 150/50 Mbps (module theoretical peak)SA: 2/1 Gbps; NSA: EA 2.6 Gbps/650 Mbps, CNV 2.2 Gbps/575 Mbps (theoretical values)

Cellular and Wi-Fi data rates are theoretical peaks. Conditions, carrier plans and site coverage affect actual performance.

06Regional frequency bands

Full 5G: RM500U-EA and RM500U-CNV

ItemRM500U-EARM500U-CNV
Region/Order suffixAsia-Pacific, Latin America; full-feature 5G region suffix -EAAsia-Pacific; local China configuration region suffix -CN
Network standard3GPP Release 15; 5G NR SA/NSA, Sub-6 GHz; LTE/WCDMA fallback3GPP Release 15; 5G NR SA/NSA, Sub-6 GHz; Release 16 and 5G new features optional; LTE/WCDMA fallback
NR SA frequency bandn1/3/5/7/8/20/28/38/40/41/66/77/78n1/3/5/8/28A/41/77*/78/79
NR NSA frequency bandn1/3/7/28/38/40/41/77/78n41*/78*/79*
NR SA RateDownlink 2 Gbps; Uplink 1 GbpsDownlink 2 Gbps; Uplink 1 Gbps
NR NSA RateDownlink 2.6 Gbps; Uplink 650 MbpsDownlink 2.2 Gbps; Uplink 575 Mbps
NR DL 4×4 MIMOn1/3/7/28/38/40/41/66/77/78n1/28A*/41/77*/78/79
NR UL 2×2 MIMOn38/40/41/77/78n41*/77*/78*/79*
NR DL 2×2 MIMOn5/8/20n3/5/8
LTE ClassDownlink Cat.12; Uplink Cat.13Downlink Cat.12; Uplink Cat.13
LTE-FDDB1/2/3/4/5/7/8/20/28/66B1/3/5/8
LTE-TDDB38/40/41B34/38/39/40/41
LTE DL 2×2 MIMOB1/2/3/4/5/7/8/20/28/38/40/41/66B1/3/5/8/34/38/39/40/41
LTE RateDownlink 600 Mbps; Uplink 150 MbpsDownlink 600 Mbps; Uplink 150 Mbps
WCDMA bandB1/2/5/8B1/5*/8
UMTS speedDownlink 42.2 Mbps; Uplink 11 MbpsDownlink 42.2 Mbps; Uplink 11 Mbps
eSIMOptional; requires operator and delivery configuration supportNot supported
Cellular antenna4-channel cellular antenna interface4-channel cellular antenna interface

Asterisks indicate optional bands or MIMO capabilities that need order confirmation. Rel-16 features are optional for the CNV configuration.

4G Cat.4

Model / Region-CN-AU-EU
China / IndiaLatin America / Australia / New ZealandEMEA/ Southeast Asia
LTE-FDDB1/3/5/8B1/2/3/4/5/ 7/8/28/66B1/3/5/7/8/ 20/28
LTE-TDDB34/38/39/ 40/41B40B38/40/41
WCDMAB1/5/8B1/2/4/5/8B1/5/8
GSMEGSM900/ DCS1800GSM850/ EGSM900 DCS1800/ PCS1900EGSM900/ DCS1800

EMEA covers Europe, the Middle East and Africa. Check the operator bands and coverage for the chosen suffix.

5G RedCap: China

Item-CN/China
5G NR SAn1/3/5/8/28/40/41/78/79
LTE-FDDB1/3/5/8
LTE-TDDB34/38/39/40/41
5G SA theoretical peak valueDownstream/Uplink 226/120 Mbps
LTE theoretical speedDownstream/Uplink 150/50 Mbps
Cellular antenna2-way cellular antenna; system conditions to be confirmed according to delivered version

Confirm the RedCap antenna and eSIM configuration for the delivered version.

Industrial acquisition and multi-link networking

Example: convert RS-485 Modbus RTU to Modbus TCP for LAN monitoring. Set LAN and WAN IPs separately and match both ends of the 1G/2.5G SFP link.

This example shows a configurable RS-485 terminal group. Choose the serial mode and wired or cellular uplink for the installation.

The three Gigabit LAN ports, one Gigabit WAN port and one 1G/2.5G SFP slot are fixed. Assign one serial port, two same-type I/O channels or None to each terminal group.

Serial and I/O groups
Wireless options

Full order modelFCT-6600-G4U1UXUF-CN
Request a quote

01Model code and resource limits
FCT-6600-G4U1Interface code + quantityUXUF/UR/UG-CN/-AU/-EU/-EA
Company + typeProduct Series4GE+1SFPAs in D2K2J2A4M4Wi-Fi 6One of three cellular optionsSelected according to cellular version

The number follows the interface letter. Two times the serial-port count plus the number of I/O channels must be 16 or less.

NONameDefinition
1Company nameFC = Feichang.
2Product TypeT = Industrial gateway.
3Product Series6600 = Industrial rail-mounted cellular router series.
4Port SpecificationsEthernetG = Gigabit RJ45; G4 = 4 copper Ethernet ports, fixed as 3 LAN + 1 WAN.
Optical EthernetU followed by the count denotes 2.5G SFP ports: U1 = 1 port, U2 = 2 ports. This model's U1 port supports 1G/2.5G auto-detection.
Serial PortD = RS-485; R = RS-232; X = RS-422, the number follows the letter.
DI/DOK = Digital input DI; J = Digital output DO
AI/AOA = current input; M = current output; V = voltage input; Y = voltage output
5Wireless ConfigurationUX = Wi-Fi 6; UF = 4G Cat.4; UR = 5G RedCap; UG = Full 5G. Choose one of the cellular codes.
6eSIM/SIMDual SIM, single standby, switchable according to configuration. eSIM available for cellular versions; EA version for full 5G is optional, and CNV version is not supported; requires operator activation.
7Region suffixCat.4: -CN/-AU/-EU; RedCap: -CN; full-feature 5G: -EA (Asia-Pacific/Latin America) or -CN (China, CNV configuration). Put the region suffix last.
02Complete order model examples
Example of order modelConfiguration
FCT-6600-G4U1D8UXUG-CN8-channel RS-485+Wi-Fi 6+Full 5G, Chinese configuration (RM500U-CNV).
FCT-6600-G4U1D8UXUG-EA8-channel RS-485+Wi-Fi 6+Full 5G, Asia-Pacific/Latin America version (RM500U-EA).
FCT-6600-G4U1D2K2J2A4M4UXUR-CN2-channel RS-485+2 DI+2 DO+4 current AI+4 current AO+Wi-Fi 6+RedCap, Chinese version.
FCT-6600-G4U1K4J4A4M4UXUF-AU4 DI+4 DO+4 current AI+4 current AO+Wi-Fi 6+Cat.4, AU version.
FCT-6600-G4U1D8UXUF-EU8-channel RS-485+Wi-Fi 6+Cat.4, EU version.

Confirm regional modem and eSIM options, SFP speed and wavelength, fiber type and distance, antennas and accessories when ordering.

Network and interfaces

3 questions
01How many LAN, WAN and fiber ports are fixed?
The router has three Gigabit LAN ports, one Gigabit WAN port and one 1G/2.5G SFP slot. Match the speed, fiber type and wavelength at both sides.
02Can I mix serial and I/O on the same router?
Yes. Any of the eight groups can provide one RS-485, RS-232 or RS-422 port, or two identical DI, DO, AI or AO channels. Groups can also be left unused.
03Can an Ethernet host read a Modbus RTU meter?
Yes, with the appropriate serial interface and Modbus RTU-to-TCP conversion. Match the serial parameters and device addresses before commissioning.

Cellular and Wi-Fi

3 questions
04Which cellular options can I order?
Choose 4G Cat.4, 5G RedCap or full Sub-6 GHz 5G. The regions offered in the order model depend on that selection.
05Can two physical SIMs be online simultaneously?
The two physical SIMs operate in single standby, with switching controlled by the configuration. The EA full-5G version can offer eSIM with carrier activation. The CNV version does not support eSIM.
06Which Wi-Fi bands are supported?
Wi-Fi 6 operates at 2.4 GHz and 5 GHz. The router supports AP and Client modes and provides two Wi-Fi antenna connections per band.

Installation and selection

3 questions
07What power supply should I use?
The router has two redundant DC 9–70 V inputs and consumes less than 12 W. Use the marked pluggable power terminals.
08How do I mount the unit?
Use the rear clip for a 35 mm DIN rail or mount the enclosure on a wall. Check the five-view drawing and allow space for the terminal plugs, antennas and fiber.
09How do I select the SFP module?
Specify 1G or 2.5G and check speed, wavelength, fiber type and distance at both ends of the link.

Send a product inquiry

Tell us the required serial and I/O groups, cellular region, SIM or eSIM option and fiber link.

We use your information only to respond to this inquiry.

Compare with your project requirements

Project checkFCT-6600-G4U1
EthernetThree Gigabit LAN ports, one Gigabit WAN port and one 1G/2.5G SFP slot.
Terminal groupsEight groups, one serial port or two I/O channels each.
Cellular4G Cat.4, 5G RedCap or full 5G. Dual SIM uses single standby.
PowerDual redundant DC 9–70 V inputs.

Browse cellular gateways