DIN-Rail RS-232 and RS-485 Serial Server

Model:FCT-1200-F1D1R1
1,808 +0

Connect RS-232 and RS-485 instruments to one network

  • Connect two types of serial instrumentsOne RS-232 channel and one RS-485 channel run independently and simultaneously on a 10/100 Mbps Ethernet uplink.
  • Keep your host software connectedUse TCP or UDP, a virtual COM port, Modbus RTU-to-TCP conversion or MQTT/JSON reporting.
  • Wire a single DC supply and mount on a rail or wallUse 5–70 V DC and a 35 mm DIN rail or wall mount. The enclosure is 97 × 54 × 32 mm.

Purpose & Applications

  • Bring an RS-485 meter and an RS-232 instrument onto the same Ethernet network. Each serial channel has separate settings and can operate at the same time.
  • Use a single unit for acquisition or two units to carry separate transparent serial links across an IP network.
  • Match the serial parameters and protocol to each instrument. Use a virtual serial port, socket access or protocol conversion for the host application.

Key Features

Per-port settings
Set baud rate, parity, data bits and stop bits per port. Supports configuration software and Modbus RTU settings.
Branch isolation
The five RS-485 grounds and supply ground are isolated. Each distribution port exposes only A/B.
Protection
6 kV surge rating per RS-485 channel and for the power input.
Panel status
PWR/D0 reports power and hub activity. D1–D4 report the corresponding distribution ports.

Terminal Pinout
PinsMarkingConnection
1–2VCC / GNDConnect 5–70 V DC positive to VCC and supply negative to GND.
3–5GND / RXD / TXDRS-232 signal ground, receive and transmit. Match receive to the peer transmit line.
6–8485 G / 485 B / 485 ARS-485 signal reference, B and A, in that order. Verify polarity against both devices.

In the front view with the terminal block at the top, the pin order runs from left to right.

Dimensions & Mounting

97 × 54 × 32 mm, 72 g. Reserve space for terminal wiring and the Ethernet cable.

Hardware & Electrical
ItemSpecification
ProcessorARM Cortex-M4 at 240 MHz.
NetworkOne 10/100BASE-T(X) RJ45 with Auto-MDI/MDIX.
Serial channelsOne RS-485 and one RS-232 with independent simultaneous communication.
Baud rate300–921,600 bps. RS-232 is limited to 256 kbps. Custom rates are supported.
Power and terminalOne 5–70 V DC input with overload and reverse-polarity protection. Eight-pin, 5.08 mm-pitch screw terminal. Under 3 W.
EnclosurePlastic, fanless, 97 × 54 × 32 mm, 72 g. 35 mm DIN rail or wall mount.
Environment−40 to +85 °C. 0–95% RH, non-condensing. MTBF above 100,000 h.
Communications & Management
ItemSpecification
Network protocolsTCP, UDP, ARP, ICMP, HTTP, DNS, DHCP, SNMP and MQTT.
Modes and conversionTCP Server/Client, UDP Server/Client, Modbus RTU-to-TCP, MQTT transparent transmission and Modbus-to-JSON conversion.
Sessions and integrationUp to four TCP or UDP sessions per serial channel. Supports virtual serial ports, TCP/IP sockets and routed networks.
Monitoring and recoverySerial framing, parameter and status monitoring. Automatic reconnection after network loss.
ConfigurationWeb, Windows tools, serial port configuration and SNMP. Supports local and remote upgrades.

Coordinate simultaneous requests to the same instrument in the host system.

Port Surge Protection
InterfacePeak VoltageConditions
Power6 kVOverload and reverse-polarity protection.
RS-232 and RS-4856 kVProtection against surges on the serial lines.
RJ454 kVProtection against surges on the Ethernet cable.

Test standard: GB/T 17626.5 / IEC 61000-4-5, 10/700 μs open-circuit waveform and 40 Ω source impedance.

Connect two kinds of instruments to a single host

Connect the RS-485 meter and the RS-232 instrument to their respective channels. The host collects both over Ethernet.

Extend two serial links across an IP network

Use one unit at each site. Map the two channels separately, match serial and application settings, and connect the client to each corresponding TCP server address and port.

Specify the mounting hardware, power supply and cables with the order.

FCT-1200-F1D1R1Request a Quote
Ordering Model
Ordering ModelConfiguration
FCT-1200-F1D1R1One RS-485, one RS-232 and one Fast Ethernet port. Single 5–70 V DC input.
Model Code
SegmentDefinition
FCT / 1200Product prefix and DIN-rail serial-server series.
F1One Fast Ethernet copper port.
D1R1One RS-485 and one RS-232 channel.

Serial channels

2 questions
01QCan RS-232 and RS-485 run at the same time?
A

Yes. The two serial channels communicate independently and can operate simultaneously.

02QWhat is the RS-232 speed limit?
A

RS-232 supports up to 256 kbps. The published serial range extends to 921,600 bps on the device.

Network access

2 questions
03QCan I connect a Modbus RTU instrument to a Modbus TCP host?
A

Yes. The unit supports RTU-to-TCP conversion. Match the serial link parameters and configure the host address and port.

04QHow many sessions are supported per serial channel?
A

Up to four TCP or UDP sessions per serial channel. Coordinate requests if several sessions share the same instrument.

Power and wiring

1 question
05QWhere do I connect the DC supply?
A

Connect 5–70 V DC to pins 1–2, VCC and supply GND. Check the front marking on the delivered unit.

Serial Interface Summary

InterfacePins and signals
RS-2323–5: GND / RXD / TXD
RS-4856–8: 485 G / 485 B / 485 A