4G IoT Gateways vs. Industrial Routers
Plan where to collect data, convert protocols and route traffic.
Angled · Click to enlarge
Front · Click to enlarge
Connect the 3 LAN, 1 WAN and SFP ports to the matching networks. Identify the delivered terminal group configuration before connecting serial lines or field signals.
The four-pin power connector has two redundant DC 9–70 V inputs. Use the marked chassis grounding point. Antenna count depends on the selected cellular version. The INIT/RST opening is on the power-side panel.
Mount the enclosure on a 35 mm DIN rail or on a wall. Reserve space for cables, antenna connectors and the optical fiber bend radius.
| Item | Specification |
|---|---|
| Power | Dual DC 9–70 V redundant inputs, internal isolation; supports polarity auto-detection, overload and reverse connection protection, and power surge protection. 4-pin 5.08 mm pluggable terminals. |
| Total Power Consumption | <12 W. |
| Item | Specification |
|---|---|
| Processor/ | Four-core ARM Cortex-A53, 1.8 GHz, 256 MB DDR. |
| Ethernet port | 3 × LAN+1 × WAN, RJ45, 10/ |
| Fiber Port | 1 × SFP optical Ethernet port, 1G/ |
| Serial ports and I/ | Up to 16 DI/ |
| Serial port communication | RS-232, RS-422, or RS-485 configured according to the selected protocol. 300–150,000 bps, line-speed non-blocking. Supports Modbus RTU to Modbus TCP. |
| Mechanical and Environmental | IP40, fanless, black anodized brushed aluminum enclosure. Operating/ |
| Reliability | MTBF >100,000 hours. |
| Item | Parameters | Technical Specifications |
|---|---|---|
| Digital input DI | Input Type | Supports dry contact, NPN or PNP transistor wet contact, and active signals. Supports active reporting and input linkage. |
| Digital output DO | Dry contact | Signal relay, 30 VDC/ |
| Wet contact/ | Optical MOS relay, 245 VDC/ | |
| Output surge protection | Wet contact uses TVS and solid discharge tube; dry contact relay output lacks this protection. | |
| Current input/ | Range | 0–20 mA (including 4–20 mA), configurable range; linked output control supported. |
| Resolution/ | 12 bits, 20,000 times/ | |
| Delay/ | <0.1 ms, 0.2%. | |
| Input resistance/ | 125 Ω/ | |
| Voltage input/ | Range | 0–10 V (including 0–5 V) or −5 to +5 V, configurable range; linked output control supported. |
| Resolution/ | 12 bits, 20,000 times/ | |
| Delay/ | <1 ms, 0.2%. | |
| Input resistance/ | 100 kΩ/ | |
| Analog sensor | Connection Method | AI supports 2-line, 3-line, or 4-line sensors. |
| Standard | Signal | Standards |
|---|---|---|
| RS-232 | RXD, TXD, GND | EIA/ |
| RS-422 | TxD+, TxD−, RxD+, RxD− | EIA/ |
| RS-485 four-wire | TxD+, TxD−, RxD+, RxD− | EIA/ |
| RS-485 two-wire | A (TX+), B (TX−), GND | EIA/ |
| Interface or test item | Rating / | Protection Notes |
|---|---|---|
| Power Interface | 6 kV (open-circuit peak) | Reduces lightning induction and switch operation surge risks on power lines; supports overload protection, DC terminals support reverse connection protection. |
| Serial interface | 6 kV (open-circuit peak) | RS-232/ |
| RJ45 Ethernet interface | 4 kV (open-circuit peak voltage) | Reduces lightning induction and switch operation surge risks on network lines. |
Surge test: GB/T 17626.5 (IEC 61000-4-5), open-circuit voltage waveform 10/700 μs, test source impedance 40 Ω.
| Item | Function |
|---|---|
| Operating System | OpenWrt. |
| Wired Connection | Static IP, DHCP, PPPoE. IP configured separately for LAN and WAN, with cross-network routing support. |
| Cellular Access | Cellular dialing, supporting APN/ |
| Dial authentication | CHAP, PAP, MS-CHAP, MS-CHAPv2, and no authentication. |
| Link Failover | Backup for wired and cellular links, wired recovery detection, and dual SIM failover. |
| Online Maintenance | Heartbeat and online detection, connection reset, watchdog, and system monitoring. |
| Routing function | NAT, PAT, DMZ, port mapping, virtual servers, and DDNS. |
| Firewall | SPI status packet detection, iptables firewall configuration, and DDoS protection. |
| Item | Function |
|---|---|
| VPN compatible | PPTP/ |
| Device Management | Web management and upgrade, SMS control, network connection and status notification. PHP local browsing and remote synchronization of local storage content. |
| Wi-Fi management | Wireless relay, WDS bridging, guest network, time period control, regional channel and transmission power adjustment. |
| Serial port transparent transmission | RS-232/ |
| Protocol Conversion | Modbus RTU to Modbus TCP. |
| MQTT data | Multi-topic publishing/ |
| Cloud platform | Supports integration with Huawei Cloud, Alibaba Cloud and Mobile Cloud. |
Dual physical SIM uses single standby. Select the SIM and failover configuration for the supplied modem. The full-5G EA option can support eSIM with operator activation. The CNV configuration does not support eSIM.
| Item | Specification |
|---|---|
| 2.4 GHz | IEEE 802.11b/ |
| 5 GHz | IEEE 802.11a/ |
| Mode and antenna | Supports AP and Client. 2 × 2 MIMO per band, total 4 antenna interfaces for two bands. |
| Item | 4G Cat.4 | 5G RedCap | Full 5G |
|---|---|---|---|
| Selection Code | UF | UR | UG |
| Standard | 3GPP Rel-9, LTE FDD/ | 3GPP Rel-17, NR SA; LTE Cat.4 fallback | Sub-6 GHz, NR SA/ |
| Theoretical down/ | FDD 150/ | NR SA 226/ | SA: 2/ |
Cellular and Wi-Fi data rates are theoretical peaks. Conditions, carrier plans and site coverage affect actual performance.
| Item | RM500U-EA | RM500U-CNV |
|---|---|---|
| Region/ | Asia-Pacific, Latin America; full-feature 5G region suffix -EA | Asia-Pacific; local China configuration region suffix -CN |
| Network standard | 3GPP Release 15; 5G NR SA/ | 3GPP Release 15; 5G NR SA/ |
| NR SA frequency band | n1/ | n1/ |
| NR NSA frequency band | n1/ | n41*/ |
| NR SA Rate | Downlink 2 Gbps; Uplink 1 Gbps | Downlink 2 Gbps; Uplink 1 Gbps |
| NR NSA Rate | Downlink 2.6 Gbps; Uplink 650 Mbps | Downlink 2.2 Gbps; Uplink 575 Mbps |
| NR DL 4×4 MIMO | n1/ | n1/ |
| NR UL 2×2 MIMO | n38/ | n41*/ |
| NR DL 2×2 MIMO | n5/ | n3/ |
| LTE Class | Downlink Cat.12; Uplink Cat.13 | Downlink Cat.12; Uplink Cat.13 |
| LTE-FDD | B1/ | B1/ |
| LTE-TDD | B38/ | B34/ |
| LTE DL 2×2 MIMO | B1/ | B1/ |
| LTE Rate | Downlink 600 Mbps; Uplink 150 Mbps | Downlink 600 Mbps; Uplink 150 Mbps |
| WCDMA band | B1/ | B1/ |
| UMTS speed | Downlink 42.2 Mbps; Uplink 11 Mbps | Downlink 42.2 Mbps; Uplink 11 Mbps |
| eSIM | Optional; requires operator and delivery configuration support | Not supported |
| Cellular antenna | 4-channel cellular antenna interface | 4-channel cellular antenna interface |
Asterisks indicate optional bands or MIMO capabilities that need order confirmation. Rel-16 features are optional for the CNV configuration.
| Model / | -CN | -AU | -EU |
|---|---|---|---|
| China / | Latin America / | EMEA/ | |
| LTE-FDD | B1/ | B1/ | B1/ |
| LTE-TDD | B34/ | B40 | B38/ |
| WCDMA | B1/ | B1/ | B1/ |
| GSM | EGSM900/ | GSM850/ | EGSM900/ |
EMEA covers Europe, the Middle East and Africa. Check the operator bands and coverage for the chosen suffix.
| Item | -CN/ |
|---|---|
| 5G NR SA | n1/ |
| LTE-FDD | B1/ |
| LTE-TDD | B34/ |
| 5G SA theoretical peak value | Downstream/ |
| LTE theoretical speed | Downstream/ |
| Cellular antenna | 2-way cellular antenna; system conditions to be confirmed according to delivered version |
Confirm the RedCap antenna and eSIM configuration for the delivered version.
This example shows a configurable RS-485 terminal group. Choose the serial mode and wired or cellular uplink for the installation.
The three Gigabit LAN ports, one Gigabit WAN port and one 1G/2.5G SFP slot are fixed. Assign one serial port, two same-type I/O channels or None to each terminal group.
| FCT- | 6600- | G4U1 | Interface code + quantity | UX | UF/ | -CN/ |
|---|---|---|---|---|---|---|
| Company + type | Product Series | 4GE+1SFP | As in D2K2J2A4M4 | Wi-Fi 6 | One of three cellular options | Selected according to cellular version |
The number follows the interface letter. Two times the serial-port count plus the number of I/O channels must be 16 or less.
| NO | Name | Definition | |
|---|---|---|---|
| 1 | Company name | FC = Feichang. | |
| 2 | Product Type | T = Industrial gateway. | |
| 3 | Product Series | 6600 = Industrial rail-mounted cellular router series. | |
| 4 | Port Specifications | Ethernet | G = Gigabit RJ45; G4 = 4 copper Ethernet ports, fixed as 3 LAN + 1 WAN. |
| Optical Ethernet | U followed by the count denotes 2.5G SFP ports: U1 = 1 port, U2 = 2 ports. This model's U1 port supports 1G/ | ||
| Serial Port | D = RS-485; R = RS-232; X = RS-422, the number follows the letter. | ||
| DI/ | K = Digital input DI; J = Digital output DO | ||
| AI/ | A = current input; M = current output; V = voltage input; Y = voltage output | ||
| 5 | Wireless Configuration | UX = Wi-Fi 6; UF = 4G Cat.4; UR = 5G RedCap; UG = Full 5G. Choose one of the cellular codes. | |
| 6 | eSIM/ | Dual SIM, single standby, switchable according to configuration. eSIM available for cellular versions; EA version for full 5G is optional, and CNV version is not supported; requires operator activation. | |
| 7 | Region suffix | Cat.4: -CN/ | |
| Example of order model | Configuration |
|---|---|
| FCT-6600-G4U1D8UXUG-CN | 8-channel RS-485+Wi-Fi 6+Full 5G, Chinese configuration (RM500U-CNV). |
| FCT-6600-G4U1D8UXUG-EA | 8-channel RS-485+Wi-Fi 6+Full 5G, Asia-Pacific/ |
| FCT-6600-G4U1D2K2J2A4M4UXUR-CN | 2-channel RS-485+2 DI+2 DO+4 current AI+4 current AO+Wi-Fi 6+RedCap, Chinese version. |
| FCT-6600-G4U1K4J4A4M4UXUF-AU | 4 DI+4 DO+4 current AI+4 current AO+Wi-Fi 6+Cat.4, AU version. |
| FCT-6600-G4U1D8UXUF-EU | 8-channel RS-485+Wi-Fi 6+Cat.4, EU version. |
Confirm regional modem and eSIM options, SFP speed and wavelength, fiber type and distance, antennas and accessories when ordering.
Tell us the required serial and I/O groups, cellular region, SIM or eSIM option and fiber link.