+8618758069661 [email protected]

16-Channel I/O Fiber Converter with 1+1 Backup

Model:FCP-1500-K16-BA
3,608 +3

Keep contact signals online when the primary fiber fails

  • Choose one-way or two-way transmissionPair K16-BA with J16-BA for 16 channels one way, or pair two K8J8-BA units for eight channels each way.
  • Switch to backup in under 1 msF1 uses the primary fiber and F2 uses a separate backup fiber. The unit returns to F1 when the primary path recovers.
  • Set each channel’s fiber-loss stateChoose normally open or normally closed for loss of the optical link, and match the relay type to the load.

Purpose & applications

  • Send on/off states, alarm contacts and equipment feedback over a point-to-point link with separate primary and backup fibers.
  • Use matched units for pump stations and industrial sites where the signal path runs between separate locations.
  • Agree on channel mapping, output type and the fiber-loss state before commissioning.

Key Features

Channels
Up to 16 one-way or 8 in each direction.
Optical link
Two FC single-fiber ports per unit, with F1 primary and F2 backup.
Outputs
Signal relay or optical MOS, selected when ordering.
Installation
Dual DC 9–70 V, DIN rail or wall mounting.

The USB marking is part of the common enclosure. This model provides contact transmission over fiber.

Digital I/O and status control
ItemTechnical specifications
Channel / DirectionSupports 1–16 channels for unidirectional or 8 channels for bidirectional transmission; this specification lists K16 input terminals, J16 output terminals, and K8J8 bidirectional configurations with 8 inputs and 8 outputs per terminal.
Signal typeSupports dry contact and wet contact; input on/off states are automatically detected, and outputs reflect the corresponding input states.
Input filteringThe digital input interface comes with a filter to eliminate interference pulses, ensuring stable digital signal output at the output.
Status IndicatorsEach channel is equipped with an on/off indicator light; optical and PWR1/PWR2 power status is visible.
Power on / no optical connectionWhen the system is powered on or the fiber is not connected, the switch state remains stable, avoiding erratic actions.
Fiber cut output settingEach digital channel can be configured as normally open or normally closed when the fiber is disconnected.
Signal relay outputDry contact; rated 30 VDC / 2 A; response time <1.2 ms; no surge protection for the output device.
Optical MOS relay outputDry contact output, maximum internal resistance 25 Ω; rated 245 VDC / 0.12 A; response time <0.6 ms; protected by TVS + solid discharge tube.
Pulse quantity / wet contactOptical MOS output 0–VCC; VCC is the power supply voltage of the device. Maximum switching frequency 50 Hz.

Two output devices are selected according to respective configurations; the rated capabilities of the optical MOS cannot be used for signal relays. Specific pins and channels are defined according to the matching wiring.

Optical interface and link budget
ItemSpecifications & Features
Interface / topology2 single-fiber FC optical ports; point-to-point connection; F1 is the primary port, F2 is the backup port, achieving 1+1 optical backup.
Main/Standby switchWhen the main fiber is broken, switch to the standby fiber; return to the main fiber after it is normal; the main/standby switch time <1 ms, and the switching process does not affect the status of the transmitted switch quantities.
Optical itemMultimode configurationSingle-mode configuration
Fiber specification50/125 μm or 62.5/125 μm8/125 μm or 9/125 μm
Transmission Distance2 km20 km standard; 0–120 km without repeaters, depending on optics
Fiber attenuation3 dB/km0.35 dB/km
Wavelength850 nm1310 nm; select 1550 nm for ultra-long distances
Transmit power−12 dBm (Min)–−9 dBm (Max)−9 dBm (Min)–−5 dBm (Max)
Receiving sensitivity−28 dBm (Min)−27 dBm (Min)
Link Budget16 dB18 dB

The listed transmit power, receiver sensitivity and link budget are for standard optics. Select extended-reach optics based on link loss and match the primary and backup paths separately. Specify distance, wavelength pairing and fiber type when ordering.

Surge protection
Interface or ItemRating / Test ConditionsProtection Notes
Digital interfaceDifferential mode 6 kV; common mode 6 kVReduce the impact of lightning strike induction and switching transient overvoltage on the signal interface.
Power InterfaceDifferential mode 6 kV; common mode 6 kVPower supply lightning protection and surge protection; also includes internal isolation, overload, and reverse connection protection.
Test Standards for Surge Protection:GB/T 17626.5 (IEC 61000-4-5) surge immunity test;Open-circuit voltage waveform:10/700 μs; Test source impedance:40 Ω.
Power, enclosure and environment
ItemTechnical specifications
Power supply / Power consumptionRedundant dual-channel DC 9–70 V input, only DC; power consumption ≤5 W.
Power terminals4-pin, 5.08 mm pitch plug terminals; two groups of PWR1/PWR2, wired according to V1−, V1+, V2−, V2+ labeling.
Electromagnetic CompatibilityMeets Class 4 industrial electromagnetic compatibility requirements.
Enclosure / heat dissipationIP40 aluminum alloy casing; fanless high-efficiency cooling, reducing repair time.
Installation / Dimensions / WeightRail or wall-mounted installation; 133×110×50 mm; 0.7 kg.
Environmental ConditionsOperating temperature: −40–+85 °C (industrial level); Storage temperature: −40–+85 °C; Operating humidity: 0%–95%, no condensation.
Reliability / WarrantyMTBF > 500000 h; All models undergo 100% burn-in test; Warranty period: 5 years.

Pump Station Contact Signals over Fiber

Carry contact states between pump stations over two independent fibers. Match F1 to F1 and F2 to F2. Check both paths and the load rating for the selected output device.

Choose the endpoint configuration

Pair with FCP-1500-J16-BA for 16 channels one way.

Specify the same optical configuration for each matched path. Optics and signal options are recorded with the order.

Ordering model FCP-1500-K16-BA Inquire About This Configuration
Model Codes
NONameDefinition
1FCP-Model prefix for this series of products
21500-Product series code.
3K16K represents digital input channels; K16 indicates 16 digital input channels.
4J16J represents digital relay outputs; J16 indicates 16 output channels; used in pairs with K16 input channels as positive-side channels.
5K8J88 digital input channels per terminal + 8 digital output channels, enabling bidirectional 8-channel transmission.
6-BA Fiber Backup-BA indicates 1+1 fiber backup: F1 as main, F2 as standby; two FC single-fiber ports are connected to the main and standby fibers respectively.
Matched Endpoints
Full Model CodeConfiguration
FCP-1500-K16-BA16-channel input unit; pair with FCP-1500-J16-BA for 16-channel unidirectional digital signal transmission.
FCP-1500-J16-BA16-channel relay output port; equipped with FCP-1500-K16-BA, used according to the channel requirement.
FCP-1500-K8J8-BA8 inputs + 8 outputs per unit; two units in pairs to achieve bidirectional 8-channel transmission.

All three configurations use 2 FC single-fiber ports, 1+1 optical backup, and redundant dual power supplies. Specify the signal type, fiber type and distance, power supply, and accessories during ordering; the optical devices at both ends are matched, and the quantity is specified per unit.

Channel configurations

2 questions
01QWhich pair carries 16 channels in one direction?+ Expand− Collapse
A
Pair FCP-1500-K16-BA at the input end with FCP-1500-J16-BA at the output end.
02QHow do I send contacts in both directions?+ Expand− Collapse
A
Use two FCP-1500-K8J8-BA units. Each unit has eight inputs and eight outputs.

Optical link and outputs

4 questions
03QHow far can the optical link reach?+ Expand− Collapse
A
Standard single-mode optics support 20 km. Extended single-mode reach up to 120 km depends on the matched optics and actual link budget. The multimode configuration is rated for 2 km.
04QWhat happens when the primary fiber fails?+ Expand− Collapse
A
Traffic transfers from F1 to F2 in under 1 ms if the backup is available. The device returns to F1 when the primary path recovers.
05QWhat happens if both fibers are disconnected?+ Expand− Collapse
A
Each digital channel can be configured for a normally open or normally closed output while the optical link is down.
06QWhich relay output should I specify?+ Expand− Collapse
A
The signal relay is rated 30 VDC / 2 A. The optical MOS output is rated 245 VDC / 0.12 A. Match the device type and ratings to the load.

Related Technical Guides

Compare Endpoint Configurations

Full Model CodeConfiguration
FCP-1500-K16-BA16-channel input unit; pair with FCP-1500-J16-BA for 16-channel unidirectional digital signal transmission.
FCP-1500-J16-BA16-channel relay output port; equipped with FCP-1500-K16-BA, used according to the channel requirement.
FCP-1500-K8J8-BA8 inputs + 8 outputs per unit; two units in pairs to achieve bidirectional 8-channel transmission.

Send a product inquiry

Tell us your application, quantity and preferred configuration.

We use your information only to respond to this inquiry.